Electrolux E24WC75HPS Wiring Diagram - Page 1

Electrolux E24WC75HPS - Icon - Professional Series 48 Bottle Wine Cooler Manual

Page 1 highlights

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A with Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time N/A 14 to 37% Wine Cooler Temperature 45º F to 65º F 45º F to 65º F Low Side Pressure (cut-in) 30 to 45 psig 208 to 310 kPa 30 to 45 psig 208 to 310 kPa Low Side Pressure (cut-out) -2 to 4 psig -14 to 28 kPa -2 to 4 psig -14 to 28 kPa High Side Pressure (last 1/3 cycle) 90 to 120 psig 621 to 827 kPa 130 to 175 psig 896 to 1207 kPa Wattage (last 1/3 cycle) 85 to 125 85 to 125 Amps (running) .75 to 1.2 .75 to 1.2 Base Voltage 115 vac (127 vac max) CONDENSER FAN MOTOR Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running WINE COOLER EVAPORATOR FAN MOTOR 1.7 each 9000 .02 each service data sheet 241957100 WINE COOLER - R134a Caution All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. NOTE Your Electrolux wine cooler has been designed for either freestanding or built-in installation. When built-in, your wine cooler does not require additional air space for top, sides or rear. In either case, the front grille must NOT be obstructed. To ease unit installation and removal, it is recommended that the cabinet rough opening dimensions be increased by at least ¼ inch over the dimensions given for your unit. All units require zero clearance when installed flush with a cabinet or wall. Electrolux stainless steel models require a minimum 2-11/16" (PRO) or 2-1/16" (DESIGNER) handle clearance when installed against a wall or cabinet that extends beyond the front edge of the unit. Unit Dimensions - ICON DESIGNER Unit Dimensions - ICON PRO important safety NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. IMPORTANT: PLEASE RETURN THIS SHEET TO IT'S ORIGINAL LOCATION.

  • 1
  • 2

SERVICE DATA SHEET
241957100
WINE COOLER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt
to make repairs due to the possibility of electrical shock.
Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.
CAUTION
All electrical parts and wiring must be shielded from torch
flame. DO NOT allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. Excessive heat will
distort the plastic liner.
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
AT MID-POINT CONTROL SETTING
Type A with Run/Start
Capacitor
65°F (18°C) Ambient
90°F (32°C) Ambient
Operating Time
N/A
14 to 37%
Wine Cooler Temperature
45º F to 65º F
45º F to 65º F
Low Side Pressure
(cut-in)
30 to 45 psig
208 to 310 kPa
30 to 45 psig
208 to 310 kPa
Low Side Pressure (cut-out)
-2 to 4 psig
-14 to 28 kPa
-2 to 4 psig
-14 to 28 kPa
High Side Pressure
(last 1/3 cycle)
90 to 120 psig
621 to 827 kPa
130 to 175 psig
896 to 1207 kPa
Wattage (last 1/3 cycle)
85 to 125
85 to 125
Amps (running)
.75 to 1.2
.75 to 1.2
Base Voltage
115 vac (127 vac max)
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
WINE COOLER EVAPORATOR FAN MOTOR
1.7 each
9000
.02 each
IMPORTANT: PLEASE RETURN THIS SHEET TO
IT’S ORIGINAL LOCATION.
Unit Dimensions - ICON DESIGNER
NOTE
Your Electrolux wine cooler has been designed for either free-
standing or built-in installation.
When built-in, your wine cooler
does not require additional air space for top, sides or rear.
In
either case, the front grille must
NOT
be obstructed.
To ease unit installation and removal, it is recommended that
the cabinet rough opening dimensions be increased by at
least ¼ inch over the dimensions given for your unit.
All units require zero clearance when installed flush with a
cabinet or wall. Electrolux stainless steel models require a
minimum
2-11/16” (PRO) or 2-1/16” (DESIGNER)
handle
clearance when installed against a wall or cabinet that extends
beyond the front edge of the unit.
Unit Dimensions - ICON PRO