Electrolux E30DF74TPS Product Specifications Sheet English - Page 3

Front

Page 3 highlights

E30DF74TPS 30" Dual-Fuel Freestanding Range E30DF74TPS professional series Minimum 5" clearance Side required from cooking surface to adjacent side walls or other 30"min. 36" vertical surfaces 18" or structures 19/16" CL min.* min. such as cabinets Wall 13" max. 18" min. 30 1/16" min. 7 3/4" 25" 10" 5" 24" min. 241/2"max. *Minimum distance required between cooking surface and cabinet bottom 8" 12" 35 3/4" min. 36" stand. 7" max. 12" 8" Hatched area is suggested gas supply/ shut-off valve location. (Supply piping can enter through cabinet side wall.) Shaded area is suggested location for electrical wall outlet which may also be located on wall in lower left corner of adjacent right cabinet. (All dimensions for outlet locations are maximum.) Depth including oven door in 90° open position - 46 1/4" 281/2" 271/2" 26" 1 1/2" Standard 6" backsplash Power supply connection (right bottom rear*) 353/4" min. 363/4" max. Gas inlet location (right bottom rear*) Adjustable legs *when viewed from front Front 41 5/8" min. 42 5/8" max. 29 7/8" 30" Dual-Fuel Freestanding Range Specifications • Product Weight - 275 Lbs. • Single phase 4-wire cable, 240 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. • Connected Load (kW Rating) @ 240 / 208 Volts = 5.0 / 3.8 kW • Amps @ 240 / 208 Volts = 21 / 19 Amps • Recommended Circuit Breaker - 40 Amps • Always consult local and national electric and gas codes. • Make sure wall coverings around range can withstand heat generated by range. • Linoleum or any other synthetic floor covering located beneath range, must be capable of withstanding minimum heat of 90° F above room temperature without shrinking, warping or discoloring. Insulating pad or 1/4" thick plywood required between range and a carpeted floor. • Do not obstruct flow of combustion air at oven vent nor around base or beneath lower front panel of range. Range requires fresh air for proper burner combustion. • Do not install range beneath any downward-blowing, overhead vent hood or air curtain. • Range ships with 3/4" factory regulator. • LP Gas conversion kit supplied. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of rangetop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 5" minimum clearance from edge of rangetop to nearest combustible wall on either side of unit. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Electrolux Major Appliances, N.A. USA • 10200 David Taylor Drive • Charlotte, NC 28262­­• 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E30DF74TPS 04/18 © 2018 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice.

  • 1
  • 2
  • 3

High standards of quality at Electrolux Home Products, Inc.
mean we are constantly working to improve our products.
We reserve the right to change specifications or
discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
• 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) •
electroluxicon.com
CANADA
• 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 •
electroluxicon.ca
E30DF74TPS
04/18
© 2018 Electrolux Home Products, Inc.
30" Dual-Fuel Freestanding Range Specifications
Product Weight – 275 Lbs.
Single phase 4-wire cable, 240 Volt, 60 Hertz AC only electrical supply
with ground required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts = 5.0 / 3.8 kW
Amps @ 240 / 208 Volts = 21 / 19 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4" thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
Do not install range beneath any downward-blowing, overhead
vent hood or air curtain.
Range ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 5" minimum clearance from edge of rangetop to nearest combustible
wall on either side of unit.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
30" Dual-Fuel Freestanding Range
E30DF74TPS
professional series
7"
max.
24"
min.
24
1
/
2
"
max.
12"
12"
*Minimum distance required
between cooking surface
and cabinet bottom
25"
10"
13"
max.
C
L
36"
min.*
Wall
30"
min.
30
1
/
16
"
min.
35
3
/
4
"
min.
36"
stand.
5"
8"
8"
Shaded area is suggested location for
electrical wall outlet which may also be
located on wall in lower left corner of
adjacent right cabinet.
(All dimensions
for outlet locations are maximum.)
Hatched area is suggested gas supply/
shut-off valve location.
(Supply piping can
enter through cabinet side wall.)
Minimum
5" clearance
required
from cooking
surface to
adjacent side
walls or other
vertical surfaces
or structures
such as cabinets
18"
min.
18"
min.
Side
1
9
/
16
"
28
1
/
2
"
27
1
/
2
"
26"
35
3
/
4
"
min.
36
3
/
4
"
max.
7
3
/
4
"
Power
supply
connection
(right
bottom
rear*)
Gas inlet
location
(right
bottom
rear*)
1
1
/
2
"
Depth
including
oven door
in 90
°
open
position –
46
1
/
4
"
Adjustable legs
Standard 6"
backsplash
Front
29
7
/
8
"
41
5
/
8
"
min.
42
5
/
8
"
max.
*when viewed
from front