Electrolux E30EC65ESS Installation Instructions - Page 2

or fire by reaching over heated surfaces, storage is provided, risk can be reduced by, horizontally - electric cooktop

Page 2 highlights

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of 13" (33 cm) 30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform and the Bottom of an Unprotected Wood or Metal Cabinet 24" (61 cm) Min. when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1/8" Flame Retardant Millboard Covered With Not Less Than No. 28 MGS Sheet Steel, 0.015" (0.4 mm) Stainless Steel, 0.024" (0.6 mm) Aluminum or 0.020" (0.5 mm) Copper L Min. K Min. Recommended Distance Between Rear Edge of Cutout and Nearest Combustible Surface Above Countertop 10" ( 25.4 cm) 18" (45.7 cm) 24" (61 cm) 12" (30.5 cm) J Min. From Edge of Cooktop to Nearest Combustible Wall (Either Side of Unit). 2 1/2" (6.4 cm) Min. From Edge of Cutout to Front Edge of Countertop Approximate Location of Junction Box Letters on this figure refer to chart on front page except for J, K & L. If a drawer is present underneath, allow at least 6½" (16.5 cm) of clearance below the countertop. CAUTION Never store flammable products in the drawer. CAUTION To eliminate the risk of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets. Model 30'' (76.2 cm) 36'' (91.4 cm) J 7½'' (19.1 cm) 7½'' (19.1 cm). K 2'' (5.1 cm) 2'' (5.1 cm) L 30'' (72.6 cm) 36'' (91.4 cm) Figure 2 - COUNTERTOP CUTOUT OPENING 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

2
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 2 – COUNTERTOP CUTOUT OPENING
Letters on this figure refer to chart on front page except for
J, K & L
.
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min.
Clearance Between the
Top of the Cooking
Platform and the Bottom
of an Unprotected Wood
or Metal Cabinet
24" (61 cm) Min.
when Bottom of Wood
or Metal Cabinet
is Protected by Not
Less Than 1/8" Flame
Retardant Millboard
Covered With Not Less
Than No. 28 MGS Sheet
Steel, 0.015" (0.4 mm)
Stainless Steel, 0.024"
(0.6 mm) Aluminum or
0.020" (0.5 mm) Copper
2 1/2" (6.4 cm) Min. From Edge of
Cutout to Front Edge of Countertop
Approximate Location
of Junction Box
18"
(45.7 cm)
J
Min. From Edge of
Cooktop to Nearest
Combustible Wall
(Either Side of Unit).
12"
(30.5 cm)
10"
( 25.4 cm)
K
Min. Recommended
Distance Between Rear
Edge of Cutout
and
Nearest Combustible
Surface Above
Countertop
24"
(61 cm)
L
Min.
CAUTION
To eliminate the risk of burns
or fire by reaching over heated surfaces,
cabinet storage space located above the
cooktop should be avoided. If cabinet
storage is provided, risk can be reduced by
installing a range hood that projects
horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
If a drawer is present
underneath, allow at least
6½" (16.5 cm) of clearance
below the countertop.
CAUTION
Never store
flammable products in the
drawer.
MODEL
J
K
L
30’’ (76.2 cm)
7½’’ (19.1 cm)
2’’ (5.1 cm)
30’’ (72.6 cm)
36’’ (91.4 cm)
7½’’ (19.1 cm).
2’’ (5.1 cm)
36’’ (91.4 cm)