Electrolux E30IC75FSS Installation Instructions

Electrolux E30IC75FSS - 30 Inch Drop-In Induction Cooktop Manual

Electrolux E30IC75FSS manual content summary:

  • Electrolux E30IC75FSS | Installation Instructions - Page 1
    SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. WARNING FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance
  • Electrolux E30IC75FSS | Installation Instructions - Page 2
    INDUCTION COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of 13" (33 cm) 30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform and the
  • Electrolux E30IC75FSS | Installation Instructions - Page 3
    product code. (Refer to the Information Sheet for the model numbers). Important Note to the Consumer Keep these instructions with your Use and Care Guide for future reference. IMPORTANT SAFETY INSTRUCTIONS • Be sure your cooktop is installed and grounded properly by a qualified installer or service
  • Electrolux E30IC75FSS | Installation Instructions - Page 4
    INSTALLATION INSTRUCTIONS DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is wire if cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes do not permit grounding to the neutral (white
  • Electrolux E30IC75FSS | Installation Instructions - Page 5
    Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Refer to your Use
  • 1
  • 2
  • 3
  • 4
  • 5

INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
30” Min. *
(76.2 cm)
B
C
A
I
F
D
G
H
E
All dimensions are stated in inches and (cm).
Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
IMPORTANT INSTALLATION INFORMATION
All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
Figure 1
Cooktop Dimensions
* 30" (76.2 cm) min. for
unprotected cabinet and
24" (61 cm) min. for cabinet
with protected bottom surface.
** Do not obstruct these areas.
Cooktop Cutout Dimensions
Printed in United States
B. WIDTH
21½
(54.6)
A. LENGTH
30¾ (78.1)
COOKTOP DIMENSIONS
G. LENGTH
I. DEPTH
4½ (11.4)
H. WIDTH
CUTOUT DIMENSIONS
F. WIDTH
19
7
/
8
(50.5)
E. LENGTH
28
7
/
8
(73.3)
D
2¾ (7)
C
2 (5.1)
DEPTH
Min.
29
5
/
8
(75.2)
Max.
29¾
(75.6)
Min.
20
3
/
8
(51.8)
Max.
20½
(52.1)
P/N 318201430 (0601) Rev. A
English – pages 1-5
Español – pages 6-10
Français - pages 11-16
4" X 8" (10.2 cm x 20.3 cm)
opening to route armored cable if a
panel is present.
Fresh air intake**
Air exhaust**
Fresh air intake**