Electrolux E36EC75HSS Specification sheet - Page 2

Electrolux Major Appliances, N.A. - model

Page 2 highlights

Electric Slide-In Cooktop E36EC75HSS 36" min. 13" max. cabinet 2" depth 35 7/8" Optional 9" stainless steel backsplash 1" min. recommended distance between rear edge of cutout and nearest combustible surface above countertop Side inset 3/8" Approximate location of junction box 10" 12" 25" min. 22" 1 1/8" 24" max. 4" x 8" opening to route armored cable 25 3/4" 7 1/2" 30" min. for unprotected cabinet 24" min. for protected surface 18" min. 7 3/4" 7 1/2" min. to nearest combustible wall (either side of unit) 3/8" 7 1/4" 35 3/16" * 35 3/16"* 35 15/16" * Both cutout dimensions are critical to proper cooktop installation. Due to variations in countertop materials it is recommended to undercut finished dimension (35-15/16") and adjust upon installation of cooktop. 36" Electric Slide-In Cooktop Specifications • Product Weight - 68 Lbs. • Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line. • Connected Load (kW Rating) @ 240 / 208 Volts = 11.8 / 8.8 kW • Amps @ 240 / 208 Volts = 49.2 / 42.6 Amps • Always consult local and national electric codes. • Respect critical dimensions as noted for proper installation of cooktop. • Allow 2" space below armored cable opening to clear electrical cable and allow space for installation of junction box on wall at back of cooktop. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 1" minimum clearance between rear edge of cutout and nearest combustible surface above countertop. • Allow 7-1/2" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • It is recommended that drawers not be used beneath cooktop. • To reduce risk of fire when using overhead cabinetry, install vent hood that projects horizontally a recommended minimum of 7" beyond bottom of cabinets. • Electric Slide-In Cooktop model E36EC75HSS is NOT approved to be used over any Electrolux ICON® Single Wall Oven. • Electric Slide-In Cooktop model E36EC75HSS (without optional backsplash) is approved to be used in combination with an Electrolux ICON® 36" Downdraft Vent. (Refer to Slide-In Cooktop / Downdraft Vent Countertop Preparation page on web for detailed installation specifications.) Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions. Optional Accessories • When replacing an existing cooktop with countertop cutout deeper than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler Kit - (PN # 903051-9010). • 9" Stainless Steel Backsplash - (PN # 903048-9010). • Black Knobs Kit - (PN # 903127-9010). Electrolux Major Appliances, N.A. USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca E36EC75HSS 04/10 © 2010 Electrolux Home Products, Inc. High standards of quality at Electrolux Home Products, Inc. mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in the U.S.A.

  • 1
  • 2
  • 3

Electric Slide-In Cooktop
E36EC75HSS
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
250 Bobby Jones Expressway
Augusta, GA 30907
1-877-4electrolux (1-877-435-3287)
electroluxicon.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxicon.ca
E36EC75HSS
04/10
© 2010 Electrolux Home Products, Inc.
Printed in the U.S.A.
36" Electric Slide-In Cooktop Specifications
Product Weight – 68 Lbs.
Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz AC
only electrical supply with ground required on separate circuit fused on
both sides of line.
Connected Load (kW Rating) @ 240/208 Volts =11.8/8.8kW
Amps @ 240/208 Volts = 49.2/42.6 Amps
Always consult local and national electric codes.
Respect critical dimensions as noted for proper installation of cooktop.
Allow 2" space below armored cable opening to clear electrical cable and
allow space for installation of junction box on wall at back of cooktop.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 1" minimum clearance between rear edge of cutout and nearest
combustible surface above countertop.
Allow 7-1/2" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
It is recommended that drawers not be used beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 7" beyond bottom
of cabinets.
Electric Slide-In Cooktop model E36EC75HSS is NOT approved to be
used over any Electrolux ICON
®
Single Wall Oven.
Electric Slide-In Cooktop model E36EC75HSS
(without optional
backsplash)
is approved to be used in combination with an
Electrolux ICON
®
36” Downdraft Vent.
(Refer to Slide-In
Cooktop/Downdraft Vent Countertop Preparation page on web for
detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
When replacing an existing cooktop with countertop cutout deeper
than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler
Kit – (PN# 903051-9010).
9" Stainless Steel Backsplash – (PN# 903048-9010).
Black Knobs Kit – (PN# 903127-9010).
7
1
/
4
"
3
/
8
"
10"
7
1
/
2
"
12"
22"
1
1
/
8
"
max.
Approximate location
of junction box
25" min.
36" min.
13"
max.
cabinet
depth
1" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
18"
min.
30" min. for
unprotected cabinet
24" min. for
protected surface
7
1
/
2
" min. to nearest
combustible wall
(either side of unit)
*35
3
/
16
"
* 35
15
/
16
"
24"
35
3
/
16
"
*Both cutout dimensions are critical to proper cooktop
installation. Due to variations in countertop materials
it is recommended to undercut finished dimension
(35-15/16") and adjust upon installation of cooktop.
4" x 8" opening to
route armored cable
Side inset
3
/
8
"
Optional 9" stainless
steel backsplash
7
3
/
4
"
25
3
/
4
"
35
7
/
8
"
2"