Electrolux EDW7505HPS Service Manual - Page 84

Alarm codes for automatic hood type dishwashers

Page 84 highlights

Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Electronic Dishwasher SERVICE MANUAL C.1 - Alarm codes for automatic hood type dishwashers When the alarm C9 appears, to facilitate fault-finding another parameter providing a more detailed indication has been introduced. The parameter is AL and is found in the DBG family. The possible cause of the anomaly can be found (see table below) according to the value of the parameter AL. With pot washers the cause that generated a b3 type alarm can also be found. E.g.: With an automatic hood type the alarm C 9 appears. Access the parameter AL in the DBG family. AL_8 ⇒ the top limit switch could be disconnected or interrupted. Hood Pot Washer S3: FC_DW (hood CLOSE) S5: FC_UP (hood OPEN) S1: DOOR_CLOSE AL_1 AL_2 AL_3 Appears with hood closed if the top limit switch (FC_UP) cuts in. Appears with hood closed, if: - the bottom limit switch (S3) returns to the rest position; - the top limit switch (S5) cuts in; - S3'' does not cut in. During lifting, the bottom limit switch (FC_DW) has not returned to the rest position. The limit switch must return to the rest position within a time given by the parameter t_5 : a) check that the motor works. b 3 During the initial lifting phase the bottom limit switch (S3) must return to the rest position within a time given by the parameter t_5 otherwise the alarm b 3 appears. - S3 could be stuck. - S5' could be disconnected. On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. - Appears if during lifting S3'' does not return to the rest position within a time t 1. AL_4 Appears if the bottom limit switch (FC_DW) cuts in during lifting. b 3 DOC. NO. 5956.446.06 ©Copyright 2005 by Electrolux Professional P.84/88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.84/88
C.1
Alarm codes for automatic hood type dishwashers
When the alarm
C9
appears, to facilitate fault-finding another parameter providing a more detailed indication has been
introduced.
The parameter is
AL
and is found in the
DBG
family
.
The possible cause of the anomaly can be found (see table below)
according to the value of the parameter
AL
.
With pot washers the cause that generated a
b3
type alarm can also be found.
E.g.: With an automatic hood type the alarm
C 9
appears.
Access the parameter
AL
in the
DBG
family.
AL_8
the top limit switch could be disconnected or interrupted.
Hood
Pot Washer
S3: FC_DW
S5: FC_UP
(hood CLOSE)
(hood OPEN)
S1: DOOR_CLOSE
AL_1
Appears with hood closed if the top
limit switch (FC_UP) cuts in.
Appears with hood closed, if:
- the bottom limit switch (S3) returns to the rest
position;
- the top limit switch (S5) cuts in;
- S3’’ does not cut in.
AL_2
During lifting, the bottom limit switch (FC_DW)
has not returned to the rest position.
The limit switch must return to the rest position
within a time given by the parameter
t_5
:
a) check that the motor works.
b 3
During the initial lifting phase the bottom limit switch
(S3) must return to the rest position within a time given
by the parameter
t_5
otherwise the alarm
b 3
appears.
- S3 could be stuck.
- S5’ could be disconnected.
On installation this alarm can occur due to incorrect
sequence of the phases: invert the two phases on the
power supply terminal board.
AL_3
-
Appears if during lifting S3’’ does not return to the rest
position within a time
t 1.
AL_4
Appears if the bottom limit switch (FC_DW)
cuts in during lifting.
b 3