Electrolux EFLS627UIW Installation Instructions English - Page 6

Clearance requirements, IMPORTANT

Page 6 highlights

6 Installation Requirements 96" (244 cm) max. 24" (61 cm) min. 3" (7.6cm) 60 sq. in. (387.1cm²) NOTE Drain hose length is 59 in. (150 cm). For installations requiring a longer drain hose, use hose P/N 137098000, available from an authorized parts distributor. Clearance requirements IMPORTANT DO NOT INSTALL YOUR WASHER: 1. In an area exposed to dripping water or outside weather conditions. 2. In an area where gasoline or other flammables are kept or stored. If the washer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. 3. On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.5 cm). To minimize vibration or movement, reinforcement of the floor may be necessary. 60 sq. in. (387.1cm²) 3" (7.6cm) closet door MINIMUM INSTALLATION CLEARANCES - Inches (cm) SIDES REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm) 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm) 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm) 0" (0 cm) 1" (2.5 cm) 0" (0 cm) 0" (0 cm) Installation in a recess or closet If washer and dryer are installed in the same closet, door ventilation is required: A minimum of 120 square inches (774.2 cm²) of opening, equally divided at the top and bottom of the door, is required. Louvered openings should be located 3 inches (7.6 cm) from bottom and top of door. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable. 1" (2.5 cm) 0" (0 cm)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

6
Installation Requirements
MINIMUM INSTALLATION CLEARANCES -
Inches (cm)
SIDES
REAR
TOP
FRONT
Alcove
0” (0 cm)
0” (0 cm)
0” (0 cm)
n/a
Under-
Counter
0” (0 cm)
0” (0 cm)
0” (0 cm)
n/a
Closet
0” (0 cm)
0” (0 cm)
0” (0 cm) 1” (2.5 cm)
Clearance requirements
0"
(0 cm)
0"
(0 cm)
Installation in a recess or closet
If washer and dryer are installed in the
same closet, door ventilation is required:
A minimum of 120 square inches (774.2
cm²) of opening, equally divided at the
top and bottom of the door, is required.
Louvered openings should be located
3 inches (7.6 cm) from bottom and top
of door. Air openings are required to be
unobstructed when a door is installed. A
louvered door with equivalent air openings
for the full length of the door is accept-
able.
60 sq. in.
(387.1cm²)
3"
(7.6cm)
60 sq. in.
(387.1cm²)
3"
(7.6cm)
closet door
1"
(2.5 cm)
0"
(0 cm)
NOTE
Drain hose length is 59 in. (150 cm). For
installations requiring a longer drain hose,
use hose P/N 137098000, available from
an authorized parts distributor.
IMPORTANT
DO NOT INSTALL YOUR WASHER:
1. In an area exposed to dripping water
or outside weather conditions.
2. In an area where gasoline or other
flammables are kept or stored. If
the washer is installed in a garage,
it must be a minimum of 18 inches
(45.7 cm) above the floor.
3. On carpet. Floor MUST be solid with
a maximum slope of 1 inch (2.5 cm).
To minimize vibration or movement,
reinforcement of the floor may be
necessary.
96"
(244 cm)
max.
24"
(61 cm)
min.