Electrolux EW30GC55GS Product Specifications Sheet (English) - Page 2

Optional Accessories, Gas Drop-In Cooktop Specifications - installation

Page 2 highlights

Gas Drop-In Cooktops EW30GC55GS 30" Gas Drop-In Cooktop Specifications • Product Weight - 43 Lbs. • Voltage Rating - 120V / 60 Hz / 15 Amps • Connected Load (kW Rating) @ 120 Volts = .001 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.) • Amps @ 120 Volts = 1.0 Amps • Always consult local and /or national electric and gas codes. • Recommended location for grounded 120V outlet is on rear wall in an 8" wide by 10" high area, positioned 22" above floor surface and 12" to right side of cooktop centerline. Access to underside of cooktop and junction box must be provided for inspection and service. • Cooktop ships with 3/4" factory regulator. • Lp conversion kit supplied. • Overhead cabinetry should not exceed a 13" maximum depth. • Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry. • Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance. • Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper. • Allow 2-1/2" minimum distance between rear edge of cutout to nearest combustible surface above countertop. • Allow 9" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit. • Drawers cannot be installed beneath this cooktop. • To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. • Gas Drop-In Cooktop model EW30GC55G is approved to be used over any Electrolux Single Wall Oven. Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.ca or supplied with product for detailed instructions. Optional Accessories • Simmer Plate - (318254208). • Wok Ring - (318254307). CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxappliances.ca EW30GC55GS 12/10 © 2008 Electrolux Major Appliances, NA High standards of quality at Electrolux Major Appliances mean we are constantly working to improve our products. We reserve the right to change specifications or discontinue models without notice. Printed in Canada

  • 1
  • 2

Gas Drop-In Cooktops
EW30GC55GS
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
Allow 2-1/2" minimum distance between rear edge of cutout to nearest
combustible surface above countertop.
Allow 9" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
Drawers cannot be installed beneath this cooktop.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Gas Drop-In Cooktop model EW30GC55G is approved to be used
over any Electrolux Single Wall Oven.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.ca or supplied with product
for detailed instructions.
Optional Accessories
Simmer Plate – (318254208).
Wok Ring – (318254307).
30" Gas Drop-In Cooktop Specifications
Product Weight – 43 Lbs.
Voltage Rating –120V/60 Hz/15 Amps
Connected Load (kW Rating) @ 120 Volts = .001 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 1.0 Amps
Always consult local and/or national electric and gas codes.
Recommended location for grounded 120V outlet is on rear wall in an
8" wide by 10" high area, positioned 22" above floor surface and 12" to
right side of cooktop centerline. Access to underside of cooktop and
junction box must be provided for inspection and service.
Cooktop ships with 3/4" factory regulator.
Lp conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.
CANADA
• 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 •