Epson ActionPrinter 3000 User Manual - Page 96

Environmental, second, Technical Specifications 7-7

Page 96 highlights

Printer Specifications Input voltage range: AC 103.5 to 132 V (120 V model) AC 198 to 242 V (220 V model) AC 216 to 264 V (240 V model) Rated current: 1.8 A (120 V model) 0.9 A (220 V model, 240 V model) Power consumption: (during self test printing in draft mode, at 10 cpi) Approx. 36 W (120 V model) Approx. 38 W (220 V model) Approx. 38 W (240 V model) Rated frequency range: 50 to 60 Hz Input frequency range: 49.5 to 60.5 Hz Insulation resistance: 10 M minimum (at DC 500 V between AC power line and chassis) Dielectric strength (between AC line and chassis): 120 V model: AC 1.0 kV (rms), 1 minute AC 1.2 kV (rms), 1 second 220 V model, 240 V model: AC 1.25 kV (rms), 1 minute AC 1.5 kV (rms), 1 second Environmental Temperature: Humidity: Operation: 41° to 95°F (5° to 35°C) Storage: -22° to 140°F (-30° to 60°C) Operation: 10% to 80% RH without condensation Storage: 5% to 85% RH without condensation Technical Specifications 7-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125

Printer Specifications
Input voltage
range:
Rated current:
Power consumption:
Rated frequency range:
Input frequency range:
Insulation
resistance:
Dielectric strength
(between AC line
and chassis):
Environmental
Temperature:
Humidity:
AC
103.5
to 132 V
(120
V model)
AC
198
to 242 V (220 V model)
AC 216 to 264 V (240 V model)
1.8 A (120 V model)
0.9 A (220 V model, 240 V model)
(during self test
printing in draft mode, at
10 cpi)
Approx. 36 W (120 V model)
Approx. 38 W (220 V model)
Approx. 38 W (240 V model)
50 to 60 Hz
49.5 to 60.5 Hz
10
M
minimum (at DC 500 V between AC
power line and chassis)
120 V model:
AC 1.0 kV (rms), 1 minute
AC 1.2 kV (rms), 1
second
220
V model, 240 V model:
AC 1.25 kV (rms), 1 minute
AC 1.5 kV (rms), 1 second
Operation: 41° to 95°F (5° to 35°C)
Storage:
-22° to 140°F (-30° to 60°C)
Operation: 10% to 80% RH without
condensation
Storage:
5% to 85% RH without
condensation
Technical Specifications 7-7