Epson FX-1050 Product Support Bulletin(s) - Page 2

W * 3.413 = 409.56 BTU/HR - manual

Page 2 highlights

PSB No: P-0060 Page: 2 of 2 If the power requirements of a particular Epson printer is not listed please refer to the appropriate User's Manual for the electrical specifications. In the event that the User's Manual is not available, locate the silver label on the back of the Epson printer. This is a reliable source for the electrical requirements. The following formula is used to calculate the electrical power requirements: VOLTAMPS is equivalent to WATTS VOLTAMPS = Volts * Amps AMPS = Voltamps/Volts BTU/HR = Watts * 3.413 Example: 120V * 1A = 120VA 120VA/120V = 1A 120VA is equivalent to 120W 120W * 3.413 = 409.56 BTU/HR Heat output is rated in BTU/HR.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

PSB No: P-0060
Page: 2 of 2
If the power requirements of a particular Epson printer is not listed please
refer to the appropriate User's Manual for the electrical specifications.
In the event that the User's Manual is not available, locate the silver label
on the back of the Epson printer.
This is a reliable source for the electrical
requirements.
The following formula is used to calculate the electrical
power requirements:
VOLTAMPS is equivalent to WATTS
VOLTAMPS = Volts * Amps
AMPS
BTU/HR
= Voltamps/Volts
= Watts * 3.413
Example:
120V *
1A
= 120VA
120VA/120V
= 1A
120VA is equivalent to 120W
120W * 3.413 = 409.56 BTU/HR
Heat output is rated in BTU/HR.