  • Fluke 116 | Fluke 116 Users Manual - Page 1
    ® 116 True-rms Multimeter Users Manual PN 2538688 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies.
  • Fluke 116 | Fluke 116 Users Manual - Page 2
    . This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period
  • Fluke 116 | Fluke 116 Users Manual - Page 3
    True-rms Multimeter Introduction The Fluke Model 116, is a battery-powered, true-rms multimeter (hereafter "the Meter") with a 6000-count display and a bar graph. This meter meets CAT III IEC 61010-1 2nd Edition standards. The IEC 61010-1 2nd Edition safety standard defines four measurement
  • Fluke 116 | Fluke 116 Users Manual - Page 4
    30 V ac rms, 42 V ac peak, or 60 V dc. These voltages pose a shock hazard. • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. • Do not use the Meter around explosive gas or vapor. • When using test leads or probes, keep
  • Fluke 116 | Fluke 116 Users Manual - Page 5
    True-rms Multimeter Safety Information • Comply with local and national safety requirements when working in hazardous locations. • Use proper protective equipment, as required by local or national authorities when working in hazardous areas. • Avoid working alone. • Use only the replacement fuse
  • Fluke 116 | Fluke 116 Users Manual - Page 6
    116 Users Manual Display 5 4 3 2 1 14 13 6 12 15 7 9 8 10 11 16 eeo02f.eps No. Symbol Meaning A s The Meter function is set to Continuity. B R The Meter function is set to Diode Test C O Input is a negative value. D Y X Unsafe voltage. Measured input voltage ≥ 30 V, or voltage
  • Fluke 116 | Fluke 116 Users Manual - Page 7
    True-rms Multimeter Display No. Symbol Meaning F M MIN MAX AVG mode enabled. VWX Maximum, minimum, average or present reading displayed G LoZ The Meter is measuring voltage or capacitiance with a low input impedance. H nµ°F°C mVµA MkΩ kHz Measurement units. I DC AC Direct current or
  • Fluke 116 | Fluke 116 Users Manual - Page 8
    resistance, capacitance, frequency, temperature, microamps and testing diodes.. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced before the Meter will operate. Calibration required. Meter calibration is required before the Meter will operate. Internal error. The Meter must be
  • Fluke 116 | Fluke 116 Users Manual - Page 9
    True-rms Multimeter Temperature from -40 °C to 400 °C (-40 °F to 752 °F) with K-type thermocouple R Diode Test. Displays OL above 2.0 V. S Farads from 1 nF to 9999 μF. $ DC current from 0.1 to 600 μA. AC current from 6.0 to 600 μA. DC-coupled. Note: All ac functions and Auto-V LoZ are true-rms
  • Fluke 116 | Fluke 116 Users Manual - Page 10
    116 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change or button press for 20 minutes. Pressing any button or turning the rotary switch awakens the Meter. To disable the Sleep mode, hold down the g
  • Fluke 116 | Fluke 116 Users Manual - Page 11
    the Meter on. True-rms Multimeter Power-Up Options Power-Up Options are canceled when you turn the Meter off and when sleep mode is activated. Button Power-Up Options f p q g Q Turns on all display segments. Disables beeper. bEEP is displayed when enabled. Enables low impedance capacitance
  • Fluke 116 | Fluke 116 Users Manual - Page 12
    116 Users Manual Measuring Resistance Testing for Continuity XWWarning eeo04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 eeo06f.eps Note The
  • Fluke 116 | Fluke 116 Users Manual - Page 13
    AC and DC Voltage Volts AC Volts DC V True-rms Multimeter Making Basic Measurements Measuring AC and DC Millivolts Millivolts AC Millivolts DC DC eeo03f.eps Using Auto Volts Selection With the function switch in the x position, the Meter automatically selects a dc or ac voltage measurement
  • Fluke 116 | Fluke 116 Users Manual - Page 14
    116 Users Manual Measuring AC and DC Current WWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to earth is > 600 V. • Use the proper switch position and range for your measurement. Flame sensor probe
  • Fluke 116 | Fluke 116 Users Manual - Page 15
    Measuring Capacitance True-rms Multimeter Making Basic Measurements Measuring Temperature RANGE eeo05f.eps Vent or 80BK Type K Pipe Thermocouple Probe eeo10f.eps XW Warning To avoid risk of electric shock, do NOT connect 80BK to live circuits. 13
  • Fluke 116 | Fluke 116 Users Manual - Page 16
    116 Users Manual Measuring Frequency XWWarning To avoid electrical shock, disregard the bar graph for frequencies >1 kHz. If the frequency of the measured signal is >1 kHz, the bar graph and Z are unspecified. AC Voltage Frequency Hz Hz V The Meter measures the frequency of a signal by counting the
  • Fluke 116 | Fluke 116 Users Manual - Page 17
    Good Diode True-rms Multimeter Making Low Impedance Capacitance Measurements Measuring Current above 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to measure currents that exceed the rating of the Meter. Make sure the Meter has the
  • Fluke 116 | Fluke 116 Users Manual - Page 18
    116 Users Manual Using the Bargraph The bar graph is like the needle on an analog meter. It has an overload indicator (>) to the right and a polarity indicator (+) to the left. Because the bar graph updates much faster than the digital display, the bar graph is useful for making peak and null
  • Fluke 116 | Fluke 116 Users Manual - Page 19
    the battery door for battery replacement: 1. Remove the test leads from the Meter. 2. Remove the battery door screw. 3. Use the finger recess to lift the door slightly. 4. Lift the door straight up to separate it from the case. True-rms Multimeter Cleaning The battery fits inside the battery door
  • Fluke 116 | Fluke 116 Users Manual - Page 20
    116 Users Manual General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Extended specifications are available at www.Fluke.com. Maximum voltage between any terminal and earth ground 600 V Surge
  • Fluke 116 | Fluke 116 Users Manual - Page 21
    True-rms Multimeter General Specifications IP Rating (dust and water protection IP42 Table 1. Accuracy Specifications Function DC millivolts DC Volts Range 600.0 mV 6.000 V 60.00 V 600.0 V Auto-V LoZ[1] True-rms 600.0 V AC millivolts[1] Truerms AC Volts[1] True-rms 600.0 mV 6.000 V 60.00 V
  • Fluke 116 | Fluke 116 Users Manual - Page 22
    116 Users Manual Function Continuity Ohms Diode test Capacitance Lo-Z Capacitance Temperature (Type K Thermocouple) Table 1 Accuracy Specifications (cont.) Range 600 Ω 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 40.00 MΩ 2.000 V Resolution 1 Ω 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.001
  • Fluke 116 | Fluke 116 Users Manual - Page 23
    True-rms Multimeter General Specifications Table 1 Accuracy Specifications (cont.) Function AC μAmps True-rms[1] (45 Hz to 1 kHz) Range 600.0 μA Resolution 0.1 μA Accuracy ± ([% of Reading] + [Counts]) 1.5 % + 3 (2.5 % + 3 >500 Hz) DC μAmps 600.0 μA 0.1 μA 1.0 % + 2 Hz (V input)[3] 99.99
  • Fluke 116 | Fluke 116 Users Manual - Page 24
    116 Users Manual Function Volts AC Volts DC Auto-V LoZ Ohms Diode Test Table 2. Input Characteristics Input Impedance (Nominal) >5 MΩ 10 MΩ
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

®
PN 2538688
July 2006, Rev. 1, 2/07
© 2006, 2007 Fluke Corporation. All rights reserved. Printed in China
All product names are trademarks of their respective companies.
116
True-rms Multimeter
Users Manual