Fluke 117 Fluke 117 Electrician Multimeter Datasheet - Page 2

Accuracy specifications - meter

Page 2 highlights

Accuracy specifications Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) DC millivolts 600.0 mV 0.1 mV 2.0 % + 3 DC volts 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer. Ohms 600.0 Ω 0.1Ω 0.9 % + 2 6.000 kΩ 0.001 kΩ 60.00 kΩ 600.0 kΩ 0.01 kΩ 0.1 kΩ 0.9 % + 1 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 1.5 % + 2 Diode test 2.000 V 0.001 V 0.9 % + 2 Capacitance 1000 nF 1 nF 10.00 µF 0.01 µF 1.9 % + 2 100.0 µF 0.1 µF 9999 µF 1 µF 100 µF to 1000 µF 1.9 % + 2 > 1000 µF 5 % + 20 Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical AC amps true-rms 6.000 A (45 Hz to 500 Hz) 10.00 A 0.001 A 0.01 A 1.5 % + 3 20 A continuous overload for 30 seconds max. DC amps 6.000 A 10.00 A 0.001 A 0.01 A 1.0 % + 3 20 A continuous overload for 30 seconds max. Hz (V or A input)2 99.99 Hz 0.01 Hz 999.9 Hz 9.999 kHz 0.1 Hz 0.001 kHz 0.1 % + 2 50.00 kHz 0.01 kHz Notes: 1 All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. 2 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.  Fluke Corporation 117 Electrician's Multimeter with Non-Contact Voltage Ordering information Fluke-117 Electrician's Multimeter with Non-Contact Voltage Included TL75 Test leads, holster, User's manual and 9V battery (installed). Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 8/2006 2634028 D-EN-N Rev A

  • 1
  • 2

Accuracy specifications
2 Fluke Corporation
117 Electrician’s Multimeter with Non-Contact Voltage
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 8/2006 2634028 D-EN-N Rev A
Fluke.
Keeping your world
up and running.
Measurement
Range
Resolution
Accuracy
± ([% of reading] + [counts])
DC millivolts
600.0 mV
0.1 mV
2.0 % + 3
DC volts
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
Auto volts
600.0 V
0.1 V
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts
1
true-rms
600.0 mV
0.1 mV
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts
1
true-rms
6.000 V
0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V
0.01 V
600.0 V
0.1 V
Continuity
600
Ω
1
Ω
Beeper on < 20
Ω
off > 250
Ω
; detects
opens or shorts of 500 µs or longer.
Ohms
600.0
Ω
0.1
Ω
0.9 % + 2
6.000 k
Ω
0.001 k
Ω
0.9 % + 1
60.00 k
Ω
0.01 k
Ω
600.0 k
Ω
0.1 k
Ω
6.000 M
Ω
0.001 M
Ω
40.00 M
Ω
0.01 M
Ω
1.5 % + 2
Diode test
2.000 V
0.001 V
0.9 % + 2
Capacitance
1000 nF
1 nF
1.9 % + 2
10.00 µF
0.01 µF
100.0 µF
0.1 µF
9999 µF
1 µF
100 µF to 1000 µF
1.9 % + 2
> 1000 µF
5 % + 20
Lo-Z capacitance
1 nF to 500 µF
10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
20 A continuous overload for 30 seconds max.
DC amps
6.000 A
0.001 A
1.0 % + 3
10.00 A
0.01 A
20 A continuous overload for 30 seconds max.
Hz (V or A input)
2
99.99 Hz
0.01 Hz
0.1 % + 2
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
50.00 kHz
0.01 kHz
Notes:
1
All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of
3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
Ordering
information
Fluke-117
Electrician’s
Multimeter with
Non-Contact Voltage
Included
TL75 Test leads, holster, User’s
manual and 9V battery (installed).