Page 2 highlights

Specifications Fluke 373 AC current AC voltage Range 600 A 600 V Max Resolution 0.1 A 0.1 V Accuracy 2 % ± 5 digits 1 % ± 5 digits DC voltage 600 V 0.1 V 1 % ± 5 digits Resistance Capacitance True-rms Continuity Hold Backlight Wire capacity 6000 Ω 10 µF to 1000 µF 0.1 Ω 1 µF 750 MCM 1 % ± 5 digits 1.9 % ± 2 digits Safety rating CAT III 600 V, CAT IV 300 V Models Old model: Fluke 337 New model: Fluke 376 Old model: Fluke 336 New model: Fluke 375 New model: Fluke 374 Old model: Fluke 335 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 334 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 333 New model: Fluke 373 Feature Changes Includes all 337 features plus: • CAT IV 600 V, CAT III 1000 V • iFlex™ 2500 A ac • 1000 V ac/dc Includes all 336 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex™ 2500 A ac • mV dc Includes all 336 features (except low pass filter) plus: • CAT IV 600 V, CAT III 1000 V Includes all 335 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex™ 2500 A ac Includes all 335 features (except inrush) plus: Includes all 334 features plus: • CAT IV 600 V, CAT III 1000 V • Optional iFlex™ 2500 A ac • True-rms Includes all 334 features (except inrush) plus: • CAT IV 300 V, CAT III 600 V Includes all 333 features plus: • CAT IV 300 V, CAT III 600 V • True-rms • mV dc • 60 kΩ • 1000 µF • 60 kΩ • 1000 µF • Min/Max/Avg • Optional iFlex™ 2500 A ac • 1000 µF • Min/Max/Avg • 600 A ac/dc • 1000 µF • Min/Max/Avg • CAT IV 300 V, CAT III 600 V • 1000 µF • 600 A ac/dc • 1000 µF • Min/Max/Avg • True-rms • 1000 µF • 600 A ac • 6000 Ω • 1000 µF 2 Fluke Corporation 373 True-rms AC Clamp Meter Ordering information 373 True-rms AC Clamp Meter Included Clamp meter, test leads, soft case, users manual Fluke. Keeping your world up and running.® Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2010 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 7/2010 3834975A D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation.

  • 1
  • 2

2 Fluke Corporation
373 True-rms AC Clamp Meter
Specifications
Fluke 373
Range
Max Resolution
Accuracy
AC current
600 A
0.1 A
2 % ± 5 digits
AC voltage
600 V
0.1 V
1 % ± 5 digits
DC voltage
600 V
0.1 V
1 % ± 5 digits
Resistance
6000
Ω
0.1
Ω
1 % ± 5 digits
Capacitance
10 µF to 1000 µF
1 µF
1.9 % ± 2 digits
True-rms
Continuity
Hold
Backlight
Wire capacity
750 MCM
Safety rating
CAT III 600 V, CAT IV 300 V
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
©2010 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 7/2010 3834975A D-EN-N
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke.
Keeping your world
up and running.
®
Ordering information
373
True-rms AC Clamp Meter
Included
Clamp meter, test leads, soft case,
users manual
Models
Feature Changes
Old model: Fluke 337
New model: Fluke 376
Includes all 337 features plus:
CAT IV 600 V, CAT III 1000 V
iFlex
2500 A ac
1000 V ac/dc
mV dc
60 k
Ω
1000 µF
Old model: Fluke 336
New model: Fluke 375
Includes all 336 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex
2500 A ac
mV dc
60 k
Ω
1000 µF
Min/Max/Avg
New model: Fluke 374
Includes all 336 features
(except low pass filter) plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex
2500 A ac
1000 µF
Min/Max/Avg
Old model: Fluke 335
New model: Fluke 374
Includes all 335 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex
2500 A ac
600 A ac/dc
1000 µF
Min/Max/Avg
New model: Fluke 373
Includes all 335 features
(except inrush) plus:
CAT IV 300 V, CAT III 600 V
1000 µF
Old model: Fluke 334
New model: Fluke 374
Includes all 334 features plus:
CAT IV 600 V, CAT III 1000 V
Optional iFlex
2500 A ac
True-rms
600 A ac/dc
1000 µF
Min/Max/Avg
New model: Fluke 373
Includes all 334 features
(except inrush) plus:
CAT IV 300 V, CAT III 600 V
True-rms
1000 µF
Old model: Fluke 333
New model: Fluke 373
Includes all 333 features plus:
CAT IV 300 V, CAT III 600 V
True-rms
600 A ac
6000
Ω
1000
µF