Fluke 376 Fluke 374, 375, 376 Users Manual - Page 23

Specifications, Electrical Specifications

Page 23 highlights

Specifications Electrical Specifications AC Current via Jaw Range 374 and 375 600.0 A 376 999.9 A Resolution 0.1 A Accuracy 2 % ± 5 digits (10-100 Hz) 2.5 % ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2 % for C.F. > 2 Clamp Meters Specifications 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Clamp Meters
Specifications
19
Specifications
Electrical Specifications
AC Current via Jaw
Range
374 and 375
......................................
600.0 A
376
.....................................................
999.9 A
Resolution
...............................................
0.1 A
Accuracy
.................................................
2 %
±
5 digits (10-100 Hz)
2.5 %
±
5 digits (100-500 Hz)
Crest Factor (50/60 Hz)
..........................
3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2 % for C.F. > 2