Fluke 902 Fluke 902 HVAC Clamp Meter Datasheet - Page 1

Fluke 902 Manual

Page 1 highlights

Fluke 902 True-rms HVAC Clamp Meter Technical Data Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with their demands. The Fluke 902 expands the existing line of quality Fluke clamp meters by delivering the features necessary to diagnose and repair HVAC systems. Combined with True RMS technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their jobs safely and accurately. N10140 Use the Fluke 902 to: • Capture flue gas temperatures • Conduct flame rod testing • Measure start and run motor capacitors • Measure performance of variable frequency drives Features include: • Capacitance • DC current to 200 uA • Contact temperature (K-type thermocouple) • True-rms • Min/Max • Hold Specifications Feature Range Accuracy Voltage dc 0 to 600.0 V 1 % ± 5 counts Voltage ac (true-rms) 0 to 600.0 V 1 % ± 5 counts (50/60 Hz) Current ac (true-rms) 0 to 600.0 A 2.0 % ± 5 counts (50/60 Hz) Current dc 0 to 200.0 µA 1.0 % ± 5 counts Resistance 0 to 9999 W 1.5 % ± 5 counts Continuity

  • 1
  • 2

Technical Data
Fluke 902
True-rms HVAC Clamp Meter
Use the Fluke 902 to:
Capture flue gas temperatures
Conduct flame rod testing
Measure start and run motor capacitors
Measure performance of variable frequency drives
Features include:
Capacitance
DC current to 200 uA
Contact temperature (K-type thermocouple)
True-rms
Min/Max
Hold
Heating, ventilation, air conditioning (HVAC)
technicians require a service tool that can
consistently keep up with their demands.
The Fluke 902 expands the existing line of
quality Fluke clamp meters by delivering the
features necessary to diagnose and repair
HVAC systems.
Combined with True RMS
technology and a CAT III 600 V rating, the
Fluke 902 helps technicians do their jobs
safely and accurately.
N10140
Specifications
Feature
Range
Accuracy
Voltage dc
0 to 600.0 V
1 % ± 5 counts
Voltage ac
(true-rms)
0 to 600.0 V
1 % ± 5 counts (50/60 Hz)
Current ac
(true-rms)
0 to 600.0 A
2.0 % ± 5 counts (50/60 Hz)
Current dc
0 to 200.0 µA
1.0 % ± 5 counts
Resistance
0 to 9999
W
1.5 % ± 5 counts
Continuity
<= 30
W
Temperature*
(Type-K
thermocouple)
-10 °C to 400 °C
(-14 °F to 752 °F)
-40 °C to -10 °C
(-40 °F to -14 °F)
± 1.0 % + 0.8 °C
(± 1.0 % + 1.5 °F) typical
± 5.0 % + 1.5 °C
(± 5.0 % + 3.3 °F) typical
Capacitance
1 µF to 1000 µF
1.9 % ± 2 counts
Warranty
Three-years
*Error does not include Type-K thermocouple errors