Frigidaire FCFE3062AS Installation Instructions - Page 2

Clearances and Dimensions

Page 2 highlights

30" ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS 1. Clearances and Dimensions a. Provide adequate clearances between the range and adjacent combustible surfaces. b. Location-Check location where the range will be installed. Check for proper electrical supply and the stability of floor. c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level. Front Typical cabinet installation view Side view Minimum to 1" wall on either side of range above 36" height. 30" Minimum 30" Minimum* Minimum to 18" cabinets on either side of range 13" Maximum depth for cabinets above range top. 25" Max. 35 ± 3/8" Min 36 ± 3/8" Max 36" Fig. 1 30" Minimum 0" clearance below cooking top and at rear of range Fig. 1 30" Fig. 2 26" Door Open 47 5/16" *30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" (0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS. TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF THE CABINETS. 2 Dashed cubed area shows where the electrical outlet should be installed for flush to the wall installation. Wall Edge Fig. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

2
30” ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be
solid and level.
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE
TOP OF THE COOKING SURFACE AND THE
BOTTOM
OF AN UNPROTECTED WOOD OR METAL CABINET;
OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD
OR METAL CABINET IS PROTECTED BY NOT LESS
THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD
COVERED WITH NOT LESS THAN NO. 28 MSG SHEET
STEEL, 0.015" (0.4 mm) STAINLESS STEEL, 0.024"
(0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER.
0" (0 mm) CLEARANCE IS THE MINIMUM FOR THE
REAR OF THE RANGE. FOLLOW ALL DIMENSION
REQUIREMENTS PROVIDED ABOVE TO PREVENT
PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND
INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY
REACHING OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE THE SURFACE
UNITS SHOULD BE AVOIDED. IF CABINET STORAGE
IS TO BE PROVIDED, THE RISK CAN BE REDUCED
BY INSTALLING A RANGE HOOD THAT PROJECTS
HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND
THE BOTTOM OF THE CABINETS.
Fig. 2
Fig. 1
Fig. 3
1”
30” Minimum*
Minimum to
wall on either
side of range
above 36” height.
36”
18”
Minimum to
cabinets on
either side
of range
25” Max.
13”
Maximum depth
for cabinets
above range top.
0” clearance below cooking top and at rear of range
Typical cabinet installation
Front
view
Side
view
30”
Minimum
30” Minimum
Dashed cubed area
shows where the electrical outlet should be
installed for flush to the wall installation.
Wall
Edge
26"
Door Open -
47
5
/
16
35 ±
3
/
8
” Min
36 ±
3
/
8
” Max
30
"
Fig. 1