Frigidaire FDL25P1 Owners Guide - Page 6
Avoid Service Checklist - review
UPC - 012505271052
View all Frigidaire FDL25P1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Avoid Service Checklist Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workman- ship or materials in this appliance. OCCURRENCE SOLUTION DEHUM IDIFIER DOES NOT OPERA TE. Plug is disconnected from outlet. Push plug firmly into wall outlet. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. The dryness level you selected has been reached. Dehumidifier automatically shuts off when selected amount of moisture has been removed from the air. If you want to remove more moisture, turn the Humidistat Control to MAX.DRY. After the dehumidifier starts, reset the control to the desired setting. Bucket not installed properly. See " Removing Collected Water." Water in the bucket has reached its preset level. Dehumidifier automatically turns off when this occurs. Empty bucket and return bucket to position. Dehumidifier is not turned on. Press CONT for maximum dryness. DEHUM IDIFIER RUNS TOO M UCH. DEHUM IDIFIER IS OPERATUNG BUT ROOM IS NOT DRY ENOUGH. W indows or doors near dehumidifier are open to outdoors. Close all windows or doors to outside. Area to be dehumidified is too large. Check with your dealer to see if capacity is adequate. Air movement through dehumidifier is blocked. Grill may be dirty. Use brush attachment of vacuum cleaner to clean grill. See " Care and Cleaning." Dehumidifier must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill. Dehumidifier has been installed or restarted recently. The higher the moistuire in the room, the longer the dehumidifier will operate. Dehumidifier is in the CONT mode and will remain on in this mode. Press the CONT button so the indicator light goes out. Then use the humidity buttons to set a higher level. Humidity setting is too high. Press the down button to a lower setting. Dehumidifier has been installed or restarted recently. The higher the moisture in the room air, the longer it takes for the room air to become dry. Dehumidifier does not have sufficient clearance to operate. Air flow to front grill is blocked. See " Selecting a Location." Room temperature is too low. Unit will not operate satisfactorily if the room temperature is below 41°F (5°C). See " Operating Conditions." Refer to causes under DEHUMIDIFIER RUNS TOO MUCH. FROST APPEARS ON COILS ABOVE BUCKET OR DRIP TRAY. Dehumidifier has been turned on recently. This is normal due to refrigerant rushing through the coil. Frost will usually disappear within 60 minutes. Room Temperature is too low. All models will operate satisfactorily at temperatures greater than 41°F (5°C). NOISE IS LIK E A FAN. Air is moving through the dehumidifier. This is a normal sound. 6