Frigidaire FFEC3625UB Installation Instructions - Page 5

circuit installation 1996 NEC, mobile home

Page 5 highlights

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS If the appliance is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire, the appliance frame MUST NOT be connected to the neutral wire of the 4-wire electrical system. Your appliance has a 3-wire cable to be connected to a 4-wire grounded junction box (see figure 6): 1. Disconnect the power supply. 2. Separate the green (or bare copper) and white appliance cable wires. 3. Cap the white wire from the power supply cable if a 3-wire appliance cable is supplied. 4. In the circuit breaker, fuse box or junction box: Connect appliance and power supply cable wires as shown in figure 6. Cable from Power Supply Ground Wire Red Wires White Wire Black Wires Your appliance has a 4-wire cable to be connected to a 4-wire grounded junction box (see figure 7): 1. Disconnect the power supply. 2. In the junction box: Connect appliance and power supply cable wires as shown in Figure 7. Ground Wire Red Wires Cable from Power Supply White Wires Ground Wire (Bare or Black Green Wire) Wires Junction Box U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 7 4-WIRE GROUNDED JUNCTION BOX Ground Wire (Bare or Green Wire) Cable from appliance Junction Box U.L.-Listed Conduit Connector (or CSA listed) Figure 6 4-WIRE GROUNDED JUNCTION BOX 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

5
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 7
4‑WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
White
Wires
Junction Box
Cable from appliance
Ground Wire
(Bare or
Green Wire)
Ground
Wire
Black
Wires
Red
Wires
U.L.-Listed Conduit
Connector (or CSA listed)
If the appliance is used in a new branch
circuit installation (1996 NEC), mobile home,
recreational vehicle, or where local codes DO
NOT permit grounding through the neutral
(white) wire, the appliance frame MUST NOT
be connected to the neutral wire of the 4‑wire
electrical system.
Your appliance has a 3‑wire cable to be connected
to a 4‑wire grounded junction box (see figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. Cap the white wire from the power supply cable if a
3-wire appliance cable is supplied.
4. In the circuit breaker, fuse box or junction box:
Connect appliance and power supply cable wires as
shown in figure 6.
Figure 6
4‑WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
White Wire
Junction Box
U.L.-Listed
Conduit
Connector (or
CSA listed)
Cable from appliance
Red
Wires
Ground Wire
(Bare or
Green Wire)
Ground Wire
Your appliance has a 4‑wire cable to be connected
to a 4‑wire grounded junction box (see figure 7):
1. Disconnect the power supply.
2. In the junction box:
Connect appliance and power supply cable wires as
shown in Figure 7.