Frigidaire FFET1222QS Wiring Diagram - Page 1
Frigidaire FFET1222QS Manual
View all Frigidaire FFET1222QS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING Type A With Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time 25 to 35% 45 to 55% Freezer Temperature 2° to 8°F (-17° to -13°C) 0° to 5°F (-18° to -15°C) Refrigerator Temperature 35° to 40°F (2° to 4°C) 35° to 40°F (1° to 4°C) Low Side Pressure (cut-in) 8 to 16 psig ( 55 to 110 kPa) 8 to 16 psig (55 to 110 kPa) Low Side Pressure (cut-out) 1 to 4 psig (7 to 28 kPa) 1 to 4 psig (7 to 28 kPa) High Side Pressure (last 1/3 cycle) 110 to 120 psig (758 to 827 kPa) 150 to 175 psig (1034 to 1207 kPa) Wattage (last 1/3 cycle) 88 to 115 88 to 115 Amps (running) 0.8 to 1.1 0.8 to 1.1 Base Voltage 115 vac (127 vac max) 115 vac (127 vac max) Refrigerant Charge 4.25 oz. (121 g) DEFROST SPECIFICATIONS Safety Thermostat Heater Defrost Thermistor Cabinet Size: 15'/16'/18'/20' Cut-in Cut-out Watts Ohms Termination 110°F (43.3°C) 135°F (57.2°C) 375 35 47°F (8.3°C) CONDENSER FAN MOTOR Watts RPM Amps 3.1 1100 CW Opposite Shaft 0.03 Running EVAPORATOR FAN MOTOR Watts RPM Amps 6.2 2600 CW 0.05 Running ICE MAKER SPECIFICATIONS Electrical 115 vac (127 vac max) 60 Hertz Thermostat Ice maker with black housing Ice maker with white housing Opens at 52°F (11°C) Opens at 48°F (8.9°C) Closes at 12°F ( -11°C) Closes at 9°F ( -12.8°C) Heater Wattage 165 W ICE MAKER CONNECTOR PLUG CONNECTIONS Wire Number Wire Color Connects to: 1 Green / Yellow Ground 2 Yellow Water Valve 3 Black Line 4 Light Blue Neutral ICE MAKER INFORMATION Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. SERVICE DATA SHEET STANDARD - AUTOMATIC DEFROST TOP MOUNT FREEZER - R134a A01511103 IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. DOOR AJAR ALARM Condition: Fresh Food Door is left open for more than 5 minutes and alarm sounds. Duration: Alarm will sound for 2 minutes, then stop. If the "Door Ajar" condition remains, the alarm will repeat every 30 minutes for two intervals. Fresh Food Light: After 15 minutes of "Door Ajar" condition, the Fresh Food light will turn off. Reset: Close the Fresh Food door or Press the Fresh Food Door switch. MANUAL DEFROST Unit will complete normal defrost cycle. enter --> Press the FF door switch 5 times in 2 secs.; Alarm sounds 5 short beeps to acknowledge MANUAL DEFROST. exit --> Cycle power to the unit or enter and exit SERVICE MODE. (See SERVICE MODE) Defrost is terminated when defrost thermistor located on the evaporator coil reaches 47°F. Safety Thermostat in the defrost circuit is a safety device only. It will interrupt power to the defrost heater at 135°F. IMPORTANT PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. SERVICE MODE SERVICE MODE will step through available tests to diagnose individual electrical circuits. Fresh Food compartment light will be OFF while in SERVICE MODE. enter/exit --> Press the door switch 3 times and hold the 4th press until 1 long beep is heard. The door switch must be pressed 4 times in 2 seconds. initiate first/next test --> Press the door switch 2 times; 2 short beeps acknowledge selection. 1 Compressor 2 Heater 3 FF Light 4 Evaporator Fan Press the FF door switch twice to start the first test. In each test, the component listed will be powered on. The component will stay powered until the next test is activated, or until 5 minutes of inactivity expire. Listen for operating sounds; feel for heat or air flow, as appropriate, to determine the result of each test. Press the FF door switch twice again to advance between tests. Two beeps will sound to confirm the next test has started. Normal Cooling Service Mode Mode Press Door Switch 3 Press Door Switch Times and Hold 4th Press Until 2 Times Long Beep Test 1: 2 Beeps Test 2: Power ON Press Door Switch Compressor ON Enters Service 2 Times Mode 2 Beeps Press Door Switch 2 Times Manual Defrost 2 Beeps to Defrost Heater To Exit Service Mode from Press Door Switch any Test Press Door Switch 2 Times 3 Times and Hold 4th Press 2 Beeps Press Door Switch 5 Times to Enter Manual Defrost. POR or Enter Service Mode to Exit Manual Defrost. Test 4: Evaporator Fan ON Press Door Switch 2 Times 2 Beeps Test 3: Fresh Food Light ON P/N A01437001 IMPORTANT START-UP NOTE: Upon 1st start-up or power cycle, the compressor will come 108 mm on after 12 seconds and run for 115 seconds. If the door switch is not cycled during this time, the compressor will cut off after 115 seconds and not turn back on for another 5 minutes. It may take up to 10 minutes for the compressor to turn on and run in normal mode. TEMPERATURE/RESISTANCE CHART FOR FRESH FOOD THERMISTOR AND DEFROST THERMISTOR °F kOHMS °F kOHMS °F kOHMS °F kOHMS -10 83.88 11 47.25 32 27.20 53 16.87 -9 81.56 12 46.02 33 27.04 54 16.49 -8 79.32 13 44.84 34 26.38 55 16.13 -7 77.15 14 43.67 35 25.75 56 16.77 -6 75.04 15 42.55 36 25.13 57 15.41 -5 73.02 16 41.45 37 24.53 58 15.07 -4 71.02 17 40.39 38 23.95 59 14.74 -3 69.08 18 39.36 39 23.38 60 14.42 -2 67.16 19 38.36 40 22.83 61 14.10 -1 65.34 20 37.39 41 22.29 62 13.79 0 63.55 21 36.44 42 21.77 63 13.49 1 61.82 22 35.53 43 21.26 64 13.21 2 60.15 23 34.63 44 20.77 65 12.92 3 58.20 24 33.78 45 20.29 66 12.65 4 56.97 25 32.94 46 19.83 67 12.38 5 55.43 26 32.13 47 19.37 68 12.11 6 53.97 27 31.33 48 18.92 69 11.85 7 52.53 28 30.57 49 18.49 70 11.60 8 51.16 29 29.83 50 18.07 71 11.36 9 49.81 30 29.10 51 17.66 72 11.12 10 48.51 31 28.39 52 17.26 73 10.88