PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient Operating Time 90 to 100% 100% Freezer Temperature -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C) SERVICE DATA SHEET A06686901 FREEZER ICE MAKER - AUTOMATIC DEFROST BOTTOM FREEZER - R134a Refrigerator Temperature 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C) IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Low Side Pressure -2 to 6 psig (-14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa) ERROR CODES SPECIAL MODES High Side Pressure (last 1/3 cycle) 85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931 kPa) Display FZ FF Interpretation Mode Display FZ FF Activate Deactivate (Press for up to 10 sec. simultaneously) Wattage (last 1/3 cycle) 30 to 50 50 to 70 -- OP Open FF Manual Defrost d F FF ^ and FF v Same to Amps (running) .4 to .8 .7 to .9 Cavity Thermistor deactivate Base Voltage 115 vac (127 vac max) DEFROST SPECIFICATIONS OP -- Open FZ Cavity Thermistor -- SH Shorted FZ Demo / Showroom Sabbath 77 77 FZ ^ and FF v Unplug to deactivate Sb Sb FZ v and FF ^ Same to deactivate Cabinet Size: 27' & 28' SD, 22' CD → ChTehcek ramt tahle Ccountnoeucttor from the powHerecaotredr → CheckDaetfIrnovsetrter Board on C→avRiteymTohverimnviesrttoerr box from the harness into the inverter board, located in the machine compartment. (PUR and WHT wires) ICs uItn-vinerter BoCaurtd-oruetceivingW11at5tsVAC fr1o1m0°pFower su1p3p5l°yF? 500 (43.3°C) (57.2°C) no yes Ohms 26.5 ComprHeessaotrer (BLTKearmndinRaEtDiownires) SH -- yes SThhoecasrrhoctmromeowidpssnstrFoe.cZsrosmorparensdsochr ewciSDknydiraesingtsgeinsmtopaasnitrcisceas Is InvCeurtt-eoruBt oard receiving 10-15 VAC and 1-5 VDC Contro4l 8B°oFard? from MainSY CF (8°C) no Is resistance across all winding UI tpoaiMrsaienqBuoaal?rd Current Air communication Temps failure; on startnoup CONDENSER FAN MOTOR SY CE UI to Main Board Notes: → Check connections from Inverter Blank UBIodairsdpltaoy,CoFmZpr^esasonrd FZ v Press and hold FF yenso LEDAsre connections from Inverter^ to deactivate illuminaBtoedard to Compressor intact? FZ FF Default Settings Automatically Temp Temp and C/F Buttons after 10 seconds no Watts 3.1 RPM Amps •11C0h0ecCkWvoltage supply. Op•poCshiteeckShanadftrepair power 0.03 Running cord harness wiring and → Check at Main Control Board SY FREEZER ICEcoMnnAecKtiEonRs. SPECIFICATIONS (BLK/WHT and RED/BLK wires) ceorrmorm; uaRInfnteivecperalartatcieoerpnCBeoroimaordpdr.es•soArrelawpnladaycsincghceocmk pfoornpeinntsb.ack-Iwoduiertensst,ifoyprianpnocdohrerecdpoaoninrreddcaatmimonaasggeedd wires before of operation • Determine whether failure isbectawueseendIbnyvetrhteer cBoomarpdoannednt, main control EF Freezer Evaporator board or wiring. Contact TCIDombperefossroer.replacing main control board. Fan Failure • Refer to Service Manual for additional information. yes no Electrical 115 vac (127 vac max) Is Main Control Board sending Replace Main Control Board. Thermostat Heater Voltage Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) 115 vac 10-15 VAC and 1-5 VDC to Inverter Board? yes Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. VCC COMPRESSOR MOTOR RESISTANCE CHECK VCC Resistance Check Replace Inverter Board Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. LINE POWER NEUTRAL ICE MAKER LT. BLUE ICE MAKER BLK BRN P-3 THERMAL CUT-OUT WATER VALVE ICE MAKER BLK RED MOTOR RED HOLD SWITCH NO LT. BLUE RED C NC THERMOSTAT P-4 NO BLK BLU NC C MOLD HEATER 165 WATTS SHUTOFF NO SWITCH GRN / YEL P-1 MOLD MOUNTING PLATE ICE MAKER NC C WATER FILL SWITCH YELLOW P-2 CAUTION All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. FREEZER ICE MAKER INFORMATION (Where Applicable) Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. Water Fill Adjustment Motor Gear Mounting Plate Screw N TUR Mounting Plate Screws Timing Gear SYSTEM DIAGNOSTIC MODE Activate: Press FZ ^ and FZ v for up to 10 sec. simultaneously. Press FF ^ to advance through tests. Deactivate: Press FF ^ for up to 10 sec. Diagnostic Mode will automatically deactivate after 10 min. of inactivity. Note: Silence alarm. • Tests marked with "*" may not be applicable to this unit and will not be displayed in System DiagnosticMode. • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. • View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. Test To activate test: Passing result -- First Screen -- Blank UI display, no LEDs illuminated. -- Second Screen -- All LED lights on UI illuminated. -- Third Screen -- Blank UI display, no LEDs illuminated. 46 Humidity Sensor Activates automatically "OP" if open, "SH" if short. AC Heater System: Displays %RH. DC Heater System: "HI" - heater should be on. "Lo" - heater should be off. %RH is displayed when humidity is between "Lo" and "HI" values; heater could be on or off. 2 Freezer Defrost Heater Press power on-off Freezer defrost heater on when "on"; off when "off". Evaporator thermistor temperature is flashed. Watch for temp increase with the heater on. It may take a few minutes for the evaporator to heat up. 12 Condenser Fan Press power on-off Fan running when "on"; stopped when "off" 43 Mullion Anticon- Press power on-off Flip Mullion Heater on when "on"; off when "off" densation Heater 38 VCC Compressor Press power on-off Compressor on when "on"; off when "off" 13 FF Lights Press power on-off FF lights on when "on"; off when "off" 15 Freezer Evaporator Fan Press power on-off Press to toggle between "off", "Lo" and "HI". A current sensor reading is flashed (units are not mA). OFF reading should be around 2. "Lo" speed reading should settle down to around 9. "HI" speed reading should settle down above 40. 20 FZ Lights Press power on-off FZ lights on when "on"; off when "off" 22 Damper Press power on-off Perform test 15 and set fan to "HI". Then, check for air flow when open "OP," and no air leaks when closed "CL". 23 FF Door Open/close FF door "CL" on UI when door closed; "OP" when open 24 FZ Door Open/close FZ door "CL" on UI when door closed; "OP" when open 29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at FF thermistor location. "OP" if open; "SH" if short 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gauge at FZ thermistor location. "OP" if open; "SH" if short 33 Ambient Therm- Activates istor @ Main automatically Board UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. "OP" if open; "SH" if short 34 Ambient Therm- Activates istor @ UI automatically UI shows temperature sensed at UI; pass if within +20°F/10°F of temperature measured with gauge at UI location. "OP" if open; "SH" if short 39 Freezer Evaporator Thermistor Activates automatically UI shows temperature sensed by freezer evaporator thermistor; pass if within 10°F of temperature measured with gauge at evaporator thermistor location. "OP" if open; "SH" if short 0- Firmware Parameters Press power on-off Displays digit sequence; record 1- Main Board Firmware Press power on-off Displays digit sequence; record 3- UI Firmware Press power on-off Displays digit sequence; record IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.