Garmin Flight Stream 110/210 GARMIN Flight Stream 110/210 Environmental Qualif - Page 2

Notes and Remarks - / 210

Page 2 highlights

Waterproofness Fluids Susceptibility Sand and Dust Fungus Resistance Salt Fog Magnetic Effect Power Input (DC Equipment) Momentary Power Interruptions 10.0 Equipment identified as Category X, no test performed 11.0 Equipment identified as Category X, no test performed 12.0 Equipment identified as Category X, no test performed 13.0 Equipment identified as Category X, no test performed 14.0 Equipment identified as Category X, no test performed 15.0 Equipment tested to Category Z 16.0 Equipment tested to Categories (A,B)XZ (See Note 1) 16.6.1.3 Unit can reset during a momentary interrupt Voltage Spike Audio Frequency Conducted Susceptibility - Power Inputs Induced Signal Susceptibility Radio Frequency Susceptibility (Radiated and Conducted) 17.0 Equipment tested to Category A 18.0 Equipment tested to Categories Z 19.0 Equipment tested to Categories ZC 20.0 Equipment tested to Category TT See Note 2 Emission of Radio Frequency Energy Lightning Induced Transient Susceptibility Lightning Direct Effects Icing Electrostatic Discharge (ESD) Fire, Flammability 21.0 Equipment tested to Category M 22.0 Equipment tested to Categories A3B2XXX See Note 2 23.0 Equipment identified as Category X, no test performed 24.0 Equipment identified as Category X, no test performed 25.0 Equipment tested to Category A 26.0 Equipment identified as Category C See Note 3 Notes and Remarks: See Garmin Report 005-00329-06 Supplemental Qualification Summary for substantiating data. 1. In-rush Current Designation Z for 14V & 28V systems: 28Volts 14 Volts 26 times the maximum steady state load in the first 23.5 times the maximum steady state load in the 3.0 mSec. (Condition 1 & 2) first 3.0 mSec. (Condition 1 & 2) < 9 x @ 3 mSec (Condition 1 & 2) < 9 x @ 0.8 mSec (Condition 1 & 2) < 4 x @ 6 mSec (Condition 1 & 2) < 4 x @ 1.4 mSec (Condition 1 & 2) < 2 x @ 8 mSec (Condition 1 & 2) < 2 x @ 2.0 mSec (Condition 1 & 2) Normal load maintained after 10mSec Normal load maintained after 10mSec 2. Qualification to additional levels and configurations are shown in Garmin Report 005-00329-06 Supplemental Qualification Summary. 3. This qualification will be per DO-160G. The plastic enclosure will be tested but the electrical components will be covered by analysis. Flight Stream 110/210 Environmental Qualification Form Page 2 of 3 005-00818-03 Rev 2

  • 1
  • 2
  • 3

Flight Stream 110/210 Environmental Qualification Form
005-00818-03
Page 2 of 3
Rev 2
Waterproofness
10.0
Equipment identified as Category X, no test performed
Fluids Susceptibility
11.0
Equipment identified as Category X, no test performed
Sand and Dust
12.0
Equipment identified as Category X, no test performed
Fungus Resistance
13.0
Equipment identified as Category X, no test performed
Salt Fog
14.0
Equipment identified as Category X, no test performed
Magnetic Effect
15.0
Equipment tested to Category Z
Power Input (DC Equipment)
Momentary Power Interruptions
16.0
16.6.1.3
Equipment tested to Categories (A,B)XZ (See Note 1)
Unit can reset during a momentary interrupt
Voltage Spike
17.0
Equipment tested to Category A
Audio Frequency Conducted
Susceptibility
Power Inputs
18.0
Equipment tested to Categories Z
Induced Signal Susceptibility
19.0
Equipment tested to Categories ZC
Radio Frequency Susceptibility
(Radiated and Conducted)
20.0
Equipment tested to Category TT
See Note 2
Emission of Radio Frequency Energy
21.0
Equipment tested to Category M
Lightning Induced Transient Susceptibility
22.0
Equipment tested to Categories A3B2XXX
See Note 2
Lightning Direct Effects
23.0
Equipment identified as Category X, no test performed
Icing
24.0
Equipment identified as Category X, no test performed
Electrostatic Discharge (ESD)
25.0
Equipment tested to Category A
Fire, Flammability
26.0
Equipment identified as Category C
See Note 3
Notes and Remarks:
See Garmin Report 005-00329-06
Supplemental Qualification Summary
for substantiating data.
1. In-rush Current Designation Z for 14V & 28V systems:
28Volts
14 Volts
26 times the maximum steady state load in the first
3.0 mSec. (Condition 1 & 2)
< 9 x @ 3 mSec (Condition 1 & 2)
< 4 x @ 6 mSec (Condition 1 & 2)
< 2 x @ 8 mSec (Condition 1 & 2)
Normal load maintained after 10mSec
23.5 times the maximum steady state load in the
first 3.0 mSec. (Condition 1 & 2)
< 9 x @ 0.8 mSec (Condition 1 & 2)
< 4 x @ 1.4 mSec (Condition 1 & 2)
< 2 x @ 2.0 mSec (Condition 1 & 2)
Normal load maintained after 10mSec
2.
Qualification to additional levels and configurations are shown in Garmin Report 005-00329-06
Supplemental Qualification Summary
.
3.
This qualification will be per DO-160G.
The plastic enclosure will be tested but the electrical components
will be covered by analysis.