Garmin GPSMAP 541s Technical Reference for Garmin NMEA 2000 Products - Page 39

Restoring Factory Default Settings

Page 39 highlights

NMEA 2000 Checklist Location Water Air outside Air inside Engine room Main cabin TEMPSOURCE Value 0 1 2 3 4 Location Live well Bait well Refrigeration Heating system Freezer TEMPSOURCE Value 5 6 7 8 13 To configure the temperature offset if the menu option is not displayed: If the temperature data displayed on the gauge connected to the GST 10 adapter is not the same as temperature data displayed on other devices, you can configure the temperature offset to increase or decrease the displayed temperature by a specific amount. 1. From the NMEA 2000 Devices list, select the GST 10 device. 2. Select an option: • For most Garmin chartplotters, select Review > Generic Config. • For other Garmin marine devices, select Config >Generic Configuration. 3. Enter the following command: "TEMPOFFSET=" 4. After the command, enter a positive or negative decimal number, followed by Done. For example, TEMPOFFSET=-2.5Done indicates that the temperature readings displayed on the gauge connected to the GST 10 adapter will be decreased by 2.5 degrees Celsius. To configure the sensor number if the menu option is not displayed: If multiple GST 10 adapters are assigned to the same NMEA 2000 temperature source, each adapter is assigned a unique sensor number automatically. If the "Invalid NMEA 2000 temperature configuration" error message appears, you must assign a unique sensor number to each adapter. For example, if two adapters are assigned the NMEA 2000 temperature source value of Live Well and the error message appears, you must assign each adapter a unique number. 1. From the NMEA 2000 Devices list, select one of the GST 10 devices assigned to the same temperature source. 2. Select an option: • For most Garmin chartplotters, select Review > Generic Config. • For other Garmin marine devices, select Config >Generic Configuration. 3. Enter the following command: "INSTANCE=" 4. After the command, enter a positive decimal number, followed by Done. 5. Repeat steps 1-4 for each GST 10 device assigned to the same temperature source. For example, if two GST 10 adapters are assigned the value of Live Well, assigning INSTANCE=1 to the first adapter and assigning INSTANCE=2 to the second adapter prevents the error message. Restoring Factory Default Settings You will lose all custom configuration settings when you restore factory default settings. 1. From the NMEA 2000 Devices list, select the GST 10 device. 2. Select an option: • For most Garmin chartplotters, select Review > Factory Defaults. • For other Garmin marine devices, select Config > Factory Defaults. 3. Select Yes. Technical Reference for Garmin NMEA 2000 Products 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Technical Reference for Garmin NMEA 2000 Products
²´
NMEA 2000 Checklist
Location
TEMPSOURCE Value
Location
TEMPSOURCE Value
Water
0
Live well
5
Air outside
1
Bait well
6
Air inside
2
Refrigeration
7
Engine room
3
Heating system
8
Main cabin
4
Freezer
13
To configure the temperature offset if the menu option is not displayed:
If the temperature data displayed on the gauge connected to the GST 10 adapter is not the same as temperature data displayed on other devices,
you can configure the temperature offset to increase or decrease the displayed temperature by a specific amount.
1. From the NMEA 2000 Devices list, select the GST 10 device.
2. Select an option:
For most Garmin chartplotters, select
Review
>
Generic Config
.
For other Garmin marine devices, select
Config
>
Generic Configuration
.
3. Enter the following command:
“TEMPOFFSET=”
4. After the command, enter a positive or negative decimal number, followed by
Done
.
For example,
TEMPOFFSET=-2.5Done
indicates that the temperature readings displayed on the gauge connected to the GST 10 adapter
will be decreased by 2.5 degrees Celsius.
To configure the sensor number if the menu option is not displayed:
If multiple GST 10 adapters are assigned to the same NMEA 2000 temperature source, each adapter is assigned a unique sensor number
automatically. If the “Invalid NMEA 2000 temperature configuration” error message appears, you must assign a unique sensor number to each
adapter.
For example, if two adapters are assigned the NMEA 2000 temperature source value of Live Well and the error message appears, you must
assign each adapter a unique number.
1. From the NMEA 2000 Devices list, select one of the GST 10 devices assigned to the same temperature source.
2. Select an option:
For most Garmin chartplotters, select
Review
>
Generic Config
.
For other Garmin marine devices, select
Config
>
Generic Configuration
.
3. Enter the following command:
“INSTANCE=”
4. After the command, enter a positive decimal number, followed by
Done
.
5. Repeat steps 1–4 for each GST 10 device assigned to the same temperature source.
For example, if two GST 10 adapters are assigned the value of Live Well, assigning
INSTANCE=1
to the first adapter and assigning
INSTANCE=2
to the second adapter prevents the error message.
Restoring Factory Default Settings
You will lose all custom configuration settings when you restore factory default settings.
1. From the NMEA 2000 Devices list, select the GST 10 device.
2. Select an option:
For most Garmin chartplotters, select
Review
>
Factory Defaults
.
For other Garmin marine devices, select
Config
>
Factory Defaults
.
3. Select
Yes
.