Garmin GPSMAP 6012 Installation Instructions - Page 12

Wiring Additional NMEA 0183 Devices, Basic NMEA 0183 Wiring

Page 12 highlights

Wiring Additional NMEA 0183 Devices The NMEA 0183 data cable included with the GPSMAP 6000/7000 series chartplotter supports the NMEA 0183 standard, which is used to wire various NMEA 0183-compliant devices, such as VHF radios, NMEA instruments, autopilots, or a computer. Basic NMEA 0183 Wiring These diagrams illustrate basic NMEA 0183 wiring used to connect your GPSMAP 6000/7000 series chartplotter to NMEA 0183-compliant devices such as an AIS or DSC device. For more-complete information on the NMEA 0183 capabilities of the GPSMAP 6000/7000 series chartplotter, see the "Advanced NMEA 0183 Wiring" section (page 13). Garmin GPSMAP 6000/7000 series chartplotter Power cable NMEA 0183 Cable wire color + - BATTERY 10-35 Vdc Wire Fuse 7.5 A - 42 V Red (power) Black (pwr gnd) Black (data GND) White Red (power) Black (pwr gnd) Black (data GND) Transmit A(+) > > orange/white transmit B(-) > > > Gray > pink Receive A(+) > receive B(-) > Wiring to a NMEA 0183-compliant Device (AIS) NMEA 0183-compliant device (AIS) Garmin GPSMAP 6000/7000 series chartplotter wire color + - BATTERY 10-35 Vdc Wire Power cable NMEA 0183 Cable Fuse 7.5 A - 42 V Red (power) Black (pwr gnd) Black (data GND) orange/white Red (power) Black (pwr gnd) Black (data GND) > > white > gray > pink unconnected Transmit Receive > > NMEA 0183-compliant device Wiring to a Single-ended NMEA 0183-compliant Device Notes: • If the NMEA 0183-compliant device has only one receiving wire (no A, B, +, or -), leave the pink wire unconnected. • If the NMEA 0183-compliant device has only one transmitting wire (no A, B, +, or -), connect the orange/white wire to ground. • Consult the installation instructions of your NMEA 0183-compliant device to identify the Transmit A(+) and B(-) wires and Receive A(+) and B(-) wires. • Use 28 AWG, shielded, twisted-pair wiring for extended runs of wire. • Solder all connections and seal them with heat-shrink tubing. 12 GPSMAP 6000/7000 Series Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

GPSMAP 6000/7000 Series Installation Instructions
Wiring Additional NMEA 0183 Devices
The NMEA 0183 data cable included with the GPSMAP 6000/7000 series chartplotter supports the NMEA 0183 standard, which is used to wire
various NMEA 0183-compliant devices, such as VHF radios, NMEA instruments, autopilots, or a computer.
Basic NMEA 0183 Wiring
These diagrams illustrate basic NMEA 0183 wiring used to connect your GPSMAP 6000/7000 series chartplotter to NMEA 0183-compliant
devices such as an AIS or DSC device. For more-complete information on the NMEA 0183 capabilities of the GPSMAP 6000/7000 series
chartplotter, see the “Advanced NMEA 0183 Wiring” section (
page 13)
.
Wiring to a NMEA 0183-compliant Device (AIS)
+
-
>
>
>
>
>
>
>
>
PINK
RECEIVE B(-)
Garmin
GPSMAP 6000/7000 series
chartplotter
NMEA 018²-compliant
device
(AIS)
BATTERY
10–35 Vdc
WIRE COLOR
WIRE
RED (POWER)
BLACK (PWR GND)
RED (POWER)
FUSE
7.5 A - 42 V
BLACK (DATA GND)
WHITE
ORANGE/WHITE
GRAY
TRANSMIT A(+)
TRANSMIT B(-)
RECEIVE A(+)
BLACK (PWR GND)
BLACK (DATA GND)
POWER
CABLE
NMEA 0183
CABLE
Wiring to a Single-ended NMEA 0183-compliant Device
+
-
>
>
>
>
>
>
Garmin
GPSMAP 6000/7000 series
chartplotter
NMEA 018²-compliant
device
BATTERY
10–35 Vdc
WIRE COLOR
WIRE
RED (POWER)
BLACK (PWR GND)
RED (POWER)
FUSE
7.5 A - 42 V
BLACK (DATA GND)
WHITE
ORANGE/WHITE
GRAY
PINK
BLACK (PWR GND)
BLACK (DATA GND)
POWER
CABLE
NMEA 0183
CABLE
TRANSMIT
RECEIVE
UNCONNECTED
Notes:
If the NMEA 0183-compliant device has only one receiving wire (no A, B, +, or -), leave the
pink
wire unconnected.
If the NMEA 0183-compliant device has only one transmitting wire (no A, B, +, or -), connect the
orange/white
wire to ground.
Consult the installation instructions of your NMEA 0183-compliant device to identify the Transmit A(+) and B(-) wires and Receive A(+)
and B(-) wires.
Use 28 AWG, shielded, twisted-pair wiring for extended runs of wire.
Solder all connections and seal them with heat-shrink tubing.