2 C CUTOUT FOR DOUBLE OVENS (2 THERMAL OVENS) NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick, shim both sides equally to establish the cutout Hwidth. Junction B Box Location (junction box may be located in adjacent cabinet) F D C J G E Cutout Depth 23-1/2" K (59.7 cm) Min. A Dim. Description 27" Double Oven 30" Double Oven with Pedestal 30" Double Oven without Pedestal A Cabinet Width 27" (68.6 cm) 30" (76.2 cm) 30" (76.2 cm) B Cutout Width 25" (63.5 cm) min. 281ø2" (72.4 cm) min. 281ø2" (72.4 cm) min. 251ø4" (64.1 cm) max. 285ø8" (72.7 cm) max. 285ø8" (72.7 cm) max. C Cutout Height 4911ø16" (126.2 cm) min. 5113ø16" (131.6 cm) min. 50 ¼" (127.64cm) 501ø8" (127.3 cm) max. 5115ø16" (131.9 cm) max. D Overlap of Oven Over Side Edges of Cutout 1" (2.5 cm) 11ø16" (1.75 cm) 11ø16" (1.75 cm) E Clearance to 23" (50.8 cm) min. Adjacent Corners, Drawers, Walls, etc., When Door Is Open 23" (53.3 cm) min. 23" (53.3 cm) min. F Overlap of Oven Top of Cutout 1" (2.5 cm) min. 1" (2.5 cm) min. 1" (2.5 cm) min. (11ø4" (3.2 cm) for PT9550, (11ø4" (3.2 cm) for PT9550, ZET2S and ZET2P) ZET2S and ZET2P) G Overlap of Oven Bottom of Cutout 1" (2.5 cm) min. 11ø4" (3.2 cm) 11ø4" (3.2 cm) H Junction Box 83ø4" (22.2 cm) max. 91ø2" (24.1 cm) max. 91ø2" (24.1 cm) max. Location right side only right side only right side only J Height to Bottom of Junction Box K Recommended Cutout Location from Floor 44" (111.8 cm) 131ø4" (33.7 cm) 47" (119.4 cm) 12" (30.5 cm) 47" (119.4 cm) 12" (30.5 cm) Continue to Section 3. 31-10979 07-14 GE 2 D CUTOUT FOR INSTALLATION OVER A WARMING DRAWER NOTE: Install the oven only with specific models listed on the label located on top of the oven. NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly grounded receptacle must be installed. Refer to installation instructions packed with the Warming Drawer for specific installation requirements. Anti-Tip Block Against Rear Wall Per Warming Drawer Requirement 2" (5.1 cm) Min. Per Warming Drawer Requirement Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

2
C
CUTOUT FOR DOUBLE OVENS
(2 THERMAL OVENS)
NOTE:
If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim
both sides equally to establish the cutout width.
Dim.
Description
27” Double Oven
30” Double Oven with
Pedestal
30” Double Oven
without Pedestal
A
Cabinet Width
27” (68.6 cm)
30” (76.2 cm)
30” (76.2 cm)
B
Cutout Width
25” (63.5 cm) min.
25
1
4
” (64.1 cm) max.
28
1
2
” (72.4 cm) min.
28
5
8
” (72.7 cm) max.
28
1
2
” (72.4 cm) min.
28
5
8
” (72.7 cm) max.
C
Cutout Height
49
11
16
” (126.2 cm) min.
50
1
8
” (127.3 cm) max.
51
13
16
” (131.6 cm) min.
51
15
16
” (131.9 cm) max.
50 ¼” (127.64cm)
D
Overlap of Oven
Over Side Edges
of Cutout
1” (2.5 cm)
11
16
” (1.75 cm)
11
16
” (1.75 cm)
E
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
23” (50.8 cm) min.
23” (53.3 cm) min.
23” (53.3 cm) min.
F
Overlap of Oven
Top of Cutout
1” (2.5 cm) min.
1” (2.5 cm) min.
(1
1
4
” (3.2 cm) for PT9550,
ZET2S and ZET2P)
1” (2.5 cm) min.
(1
1
4
” (3.2 cm) for PT9550,
ZET2S and ZET2P)
G
Overlap of Oven
Bottom of Cutout
1” (2.5 cm) min.
1
1
4
” (3.2 cm)
1
1
4
” (3.2 cm)
H
Junction Box
Location
8
3
4
” (22.2 cm) max.
right side only
9
1
2
” (24.1 cm) max.
right side only
9
1
2
” (24.1 cm) max.
right side only
J
Height to Bottom
of Junction Box
44” (111.8 cm)
47” (119.4 cm)
47” (119.4 cm)
K
Recommended
Cutout Location
from Floor
13
1
4
” (33.7 cm)
12” (30.5 cm)
12” (30.5 cm)
2
D
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE:
Install the oven only with specific models listed on the label located on top of the oven.
NOTE:
Additional clearances between cutouts may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with
the Warming Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.
Continue to Section 3.
H
B
C
K
F
G
D
A
J
E
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
Cutout Depth
23-1/2”
(59.7 cm) Min.
31-10979
07-14
GE