Installation Instructions Electric Dryer 09 Questions or Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.GEAppliances.com (US) PEDESTALS FOR DRYERS (comes with individual installation instructions) Three models available: - SBSD227F - SBSD107H - SBSD137H BEFORE YOU BEGIN Read these instructions completely and carefully. • IMPORTANT- Save these instructions for local inspector's use. • IMPORTANT- Observe all governing codes and ordinances. • Note to Installer - Be sure to leave these instructions with the customer. • Note to Customer - Keep these instructions with your Use and Care Book for future reference. • Before the old dryer is removed from service or discarded, remove the dryer door. • Service information and the wiring diagram are located in the control console. • Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children. • Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system. WARNING - RISK OF FIRE • To reduce the risk of severe injury or death, follow all installation instructions. • Clothes dryer installation must be performed by a qualified installer. • Install the clothes dryer according to these instructions and in accordance with local codes. • This dryer must be exhausted to the outdoors. • Use only 4" rigid metal ducting for exhausting the clothes dryer to the outdoors. • DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 5 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire. • Do not install or store this appliance in any location where it could be exposed to water and or weather. • Save these instructions. (Installers: Be sure to leave these instructions with the customer). NOTE: Installation and service of this dryer requires basic mechanical and electrical skills. It is your responsibility to contact a qualified installer to make the electrical connections. TOOLS YOU WILL NEED SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER PHILLIPS SCREWDRIVER LEVEL MATERIALS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT 4" DIA. METAL CLAMPS (2) ELBOW 4" DIA. FLEXIBLE METAL (SEMI-RIGID) OR UL LISTED TRANSITION DUCT 4" SPRING (IF NEEDED) CLAMPS (2) KIT WX08X10077 (INCLUDES 2 ELBOWS) 4" DIA. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) DUCT TAPE EXHAUST HOOD SAFETY GLASSES 3/4" STRAIN GLOVES RELIEF UL RECOGNIZED DRYER POWER CORD KIT (NOT PROVIDED WITH DRYER) UL RATED 120/240V,30A WITH 3 OR 4 PRONGS. IDENTIFY THE PLUG TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD. Step 1 Prepare the Area and Exhaust for Installation of New Dryer (see section 1). Step 2 Check and Ensure the Existing External Exhaust is Clean (see section 1) and Meets Attached Installation Specifications (see section 3). Step 3 Remove the Foam Shipping Pads (see section 1). Step 4 Move the Dryer to the Desired Location. Step 5 Connect the Power Supply (see section 2). Step 6 Connect the External Exhaust (see section 4). Step 7 Level Your Dryer (see section 5). Step 8 Check the Operation of the Power Supply and Venting. Step 9 Place the Owners Manual and the Installation Instructions in a Location Where They Will Be Noticed By the Owner. For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7. For Mobile or Manufactured Home see, section 8. For side or bottom exhaust, see section 9. 500A436P009_Rev0 Pub # 31-16228

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Questions or Installation? Call: 1-800-GECARES (US)
or
Visit our Web site at:
www.GEAppliances.com (US)
Installation
Instructions
Electric Dryer
09
Step 1
Prepare the Area and Exhaust for Installation of New
Dryer (see section 1).
Step 2
Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 3).
Step 3
Remove the Foam Shipping Pads (see section 1).
Step 4
Move the Dryer to the Desired Location.
Step 5
Connect the Power Supply (see section 2).
Step 6
Connect the External Exhaust (see section 4).
Step 7
Level Your Dryer (see section 5).
Step 8
Check the Operation of the Power Supply and
Venting.
Step 9
Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation, see section 6.
For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8.
For side or bottom exhaust, see section 9.
500A436P009_Rev0
Pub # 31-16228
PEDESTALS FOR DRYERS
(comes with individual installation instructions)
Three models available:
- SBSD227F
- SBSD137H
- SBSD107H
NOTE:
Installation and service of this dryer
requires basic mechanical and electrical skills.
It is your responsibility to contact a qualified
installer to make the electrical connections.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT-
Save these instructions for local
inspector’s use.
IMPORTANT-
Observe all governing codes and
ordinances.
Note to Installer
- Be sure to leave these instructions with
the customer.
Note to Customer
- Keep these instructions with your Use
and Care Book for future reference.
Before the old dryer is removed from service or discarded,
remove the dryer door.
Service information and the wiring diagram are located in
the control console.
Do not allow children on or in the appliance.
Close super-
vision of children is necessary when the appliance is used
near children.
Install the dryer where the temperature is above 50°F for
satisfactory operation of the dryer control system.
MATERIALS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER CORD
KIT (NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
- RISK OF FIRE
WARNING
To reduce the risk of severe injury or death, follow all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance
with local codes.
This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the
outdoors.
Do not install or store this appliance in any location where it could be
exposed to water and or weather.
Save these instructions.
(Installers: Be sure to leave these instructions with
the customer).
DO NOT install a clothes dryer with flexible plastic ducting materials.
If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed
and installed in accordance with the instructions found in "Connecting The
Dryer To House Vent" on page 5 of this manual.
Flexible venting materials
are known to collapse, be easily crushed, and trap lint.
These conditions will
obstruct dryer airflow and increase the risk of fire.