GE DPVH890EJMG Owners Manual - Page 24
Installation Instructions, WARNING, CONNECTING AN ELECTRIC DRYER cont., CONNECTING DRYER USING 3-WIRE
UPC - 084691187264
View all GE DPVH890EJMG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Installation Instructions CONNECTING AN ELECTRIC DRYER (cont.) CONNECTING DRYER USING 3-WIRE CONNECTION If required, by local code, install external ground (not provided) to grounded metal, cold water pipe, or other established ground determined by a qualified electrician. Green Ground Screw Ground Strap Strain Relief Hot Wire Bracket Screws (3) Cover Neutral (white) Hot Wire 3/4″ UL Recognized Strain Relief 3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied) 1. Turn off the circuit breaker(s) (30 amp) or remove the dryer's circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. 3. Remove the power cord cover located at the lower back. 4. Install 3/4-in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief. 5. Connect power cord as follows: A. Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2). B. Connect the neutral (white) line to the center of the terminal block (marked N). 6. Be sure ground strap is connected to neutral (center) terminal of block and to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely. 7. Properly secure power cord to strain relief. 8. Reinstall the cover. WARNING - NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK. 24