JVM3160RF GE® 1.6 cu. ft. Over-the-Range Microwave Oven Dimensions and Installation Information (in inches) Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully. Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust. Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet. Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts. Duct A. Rectangular-To-round Transition Adaptor B. Wall Cap C. 90° Elbow D. 45° Elbow E. 90° Elbow F. 45° Elbow G. Roof Cap Equivalent Feet 5 ft. 40 ft. 10 ft. 5 ft. 25 ft. 5 ft. 24 ft. Optional Accessories (Available at additional cost) Filler Panel Kits JX40 and JX46 When replacing a 36" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between ­cabinets only; not for end-of-cabinet installation. Each kit ­contains two 3"-wide filler panels. Filter Kit JX81L- Recirculating Charcoal Filter Kit To be used when the Spacemaker microwave oven cannot be vented to the outside. For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories Specification Revised 7/13 340169

  • 1
  • 2
  • 3

For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
340169
Specification Revised 7/13
Listed by
Underwriters
Laboratories
JVM3160RF
GE
®
1.6 cu. ft. Over-the-Range Microwave Oven
Hood Exhaust Duct:
Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Connection:
The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6" diameter duct
Rear Exhaust:
If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length:
For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.
Elbows, Transitions, Wall and Roof Caps
, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equivalent length of all transitions
and adaptors plus the lengths of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
Duct
Equivalent Feet
A.
Rectangular-To-round
Transition Adaptor
5 ft.
B.
Wall Cap
40 ft.
C.
90° Elbow
10 ft.
D.
45° Elbow
5 ft.
E.
90° Elbow
25 ft.
F.
45° Elbow
5 ft.
G.
Roof Cap
24 ft.
Optional Accessories (Available at additional cost)
Filler Panel Kits JX40 and JX46
When replacing a
36" range hood,
this kit fills in the additional width to
provide a custom built-in
appearance. For installation
between cabinets only; not
for end-of-cabinet installation.
Each kit contains two 3"-wide
filler panels.
Filter Kit JX81L–
Recirculating Charcoal
Filter Kit
To be used
when the Spacemaker
microwave oven
cannot be vented to
the outside.
Dimensions and Installation Information (in inches)