GE NX-1308E User Manual - Page 59
Ansi / Sia Cp-01 Requirements - led keypad manual
UPC - 851670000254
View all GE NX-1308E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
ANSI / SIA CP-01 REQUIREMENTS IMPORTANT NOTE: UL requirements take priority over SIA requirements. To meet SIA CP-01 requirements - • Minimum System Requirements: 1 control panel; 2 keypads (or 1 keypad per partition for multi-partitioned systems) • Remote arming shall NOT be enabled in SIA classified installations. • Off-premise transmission must be in the SIA format. • The Abort window and Entry Delay must not exceed 1 minute. • CAUTION - A call waiting cancel on a non-call waiting line will prevent successful connection to the central station. CP-01 Feature Description Feature Description as shown in manual Program Loc Seg / Opt Factory Default Exit Time Exit 1 Delay 24 2 60 Exit 2 Delay 24 4 60 Progress Annuncation / Disable - for Silent Exit Silent Keypad Option 9 3 2 All annunciators enabled Exit Time Restart This feature is non-programmable in the panel. Auto Stay Arm on Unvacated Premises Auto Bypass 23 1 / 3 Enabled Exit Time and Progress This feature is non-programmable in the panel. -- Exit time and progress are always enabled. Annunciation / Disable - for Remote Arm Entry Delay(s) Entry 1 Delay 24 1 30 Entry 2 Delay 24 3 30 Abort Window - for Non-Fire Zones Dialer Delay 40 8 30 Abort Window Time - for Non-Fire Zones Dialer Delay 40 8 30 Abort Annunciation This feature is non-programmable in the panel. -- Flashing Cancel LED goes off when disarming. Cancel Annunciation Cancel 23 3 / 6 Enabled Duress Feature Duress 44 Disabled Cross Zoning 2 Trips on Cross Zone 37 5 / 4 Disabled Keypad sounds on Cross Zone trip 39 5 Disabled Zone Type Characteristic 111 3 / 4 Disabled Programmable Cross Zoning Time Cross Zone Time 40 6 5 minutes Swinger Shutdown Swinger Shutdown Count 38 n/a Enabled for 1 trip Swinger Shutdown Disable Swinger Shutdown Count 38 n/a Enabled for 1 trip Fire Alarm Verification Fire Alarm Verification Time 40 9 Disabled Call Waiting Cancel Must be programmed as part of the 0 n/a n/a phone number Default Changes (from prior versions): Recent Closing 23 3 / 7 Enabled Exit Error 23 3 / 8 Enabled Power Up Delay 40 3 60 sec. CP-01 Required Setting 45 - 240 sec. 45 - 240 sec. Allowed (individual keypads may be disabled) Enabled Enabled Enabled (may be disabled for remote arming) 30 - 240 sec. 30 - 240 sec. Enabled (may be disabled by zone/ zone type) 15 - 45 sec. NOTE: Combined Abort window and Entry Delay must not exceed 1 minute. Enabled Enabled Disabled Required Allowed For all non-fire zones, shut down at 1-2 trips Allowed Required (depends on panel & sensors) Required (depends on user phone line)