GE WPDH8800JMG Owners Manual - Page 16
Installation Instructions, LOCATION OF YOUR WASHER, ROUGH-IN DIMENSIONS
UPC - 084691169697
View all GE WPDH8800JMG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Installation Instructions LOCATION OF YOUR WASHER Do Not Install the Washer: 1. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60°F (15.6°C) for proper washer operation. 2. In an area where it will come in contact with curtains or drapes. 3. On carpet. The floor MUST be a hard surface with a maximum slope of 1/2″ per foot (1.27 cm per 30 cm). To make sure the washer does not vibrate or move, you may have to reinforce the floor. NOTE: If floor is in poor condition, use 3/4″ impregnated plywood sheet solidly attached to existing floor covering. IMPORTANT: Minimum Installation Clearances • When installed in alcove: Sides, Rear, Top = 0″ (0 cm) • When installed in closet: Sides, Rear, Top = 0″ (0 cm), Front = 1″ (2.54 cm) • Closet door ventilation openings required: 2 louvers each 60 square in. (387 cm2), located 3″ (7.6 cm) from top and bottom of door ROUGH-IN DIMENSIONS FRONT 27.0" (68.6 cm) SIDE 32.1" (81.5 cm) 39.2"* (99.5 cm) 39.2"* (99.5 cm) *NOTE: With Washer Legs: 40.5" (102.5 cm) (0.75" adjustability) With Pedestal: 53.75" (136.6 cm) (0.75" adjustability) Stacked: 82.75" (209.8 cm) 16