Haier 3HUM18HB03 User Manual - Page 3

Operation - air conditioner

Page 3 highlights

Operation Base Operation Remote controller ON/OFF   FAN  MODE   SWING TIMER POWER/SOFT CLOCK LIGHT SET SLEEP LOCK RESET 1. Unit start Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY HEAT FAN 3.Select temp.setting Press  button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO LO MED HI Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. Operation Mode AUTO COOL DRY HEAT FAN Remote Controller Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature. In DRY mode , when room temperature becomes lower than temp.setting+2o C, unit will run intermittently at LOW speed regardless of FAN setting. In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available. Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes: Room Designated Timer Fan Operation temperature temperature mode speed mode Above 23oC Below 23oC 26oC 23oC No AUTO COOL No AUTO HEAT emergency operation switch Pi It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode. Test operation: Test operation switch is the same as emergency switch. Use this switch in the test operation when the room temperature is below 16oC, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi". Under this operation mode,the fan motor of indoor unit will run in high speed. test operation switch Pi Pi Air Flow Direction Adjustment 1.Status display of air flow Vertical flap Pos.1 blank Pos.2 Pos.3 Pos.4 (Auto swing) 2.Left and right air flow adjustment(manual) Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig. ' Cautions: When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur. Note: When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

3
Operation
Air Flow Direction Adjustment
AUTO
COOL
DRY
FAN
HEAT
2.Select operation mode
Press FAN button. For each press, fan speed
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Vertical flap
Pos.1 blank
Pos.2
Pos.3
Pos.4
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency operation and test operation
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
Operation
Mode
AUTO
Remote
Controller
Note
COOL
DRY
HEAT
FAN
In DRY mode , when room temperature becomes
lower than temp.setting+2
o
C, unit will run
intermittently at LOW speed regardless of FAN
Under the mode of auto operation, air conditioner
will automatically select Cool or Heat operation
according to room temperature
to AUTO the air conditioner automatically adjusts
temperature.
When FAN is set
the fan speed according to room
In FAN operation mode , the unit will not operate in
COOL or HEAT mode but only in FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled. In FAN mode, sleep operation
setting.
is not available.
AUTO
LO
MED
HI
ON/OFF
FAN
MODE
LOCK
RESET
SWING
TIMER
CLOCK
SET
SLEEP
POWER/SOFT
LIGHT
test operation
switch
Pi
Pi
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C
Below 23
o
C
23
o
C
26
o
C
No
AUTO
AUTO
COOL
HEAT
No
Pi
emergency
operation switch
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ration switch is the same as emergency
switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
In HEAT mode, warm air will blow out after a short
period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.