Haier AB092ACBHA User Manual

Haier AB092ACBHA Manual

Haier AB092ACBHA manual content summary:

  • Haier AB092ACBHA | User Manual - Page 1
    CASSETTE AIR CONDITIONER Operation & Installation Manual AB092ACBHA AU092AABHA (HBU-09HA03/R1(B)) AB122ACBHA AU122AABHA (HBU-12HA03/R1(B)) No.0010572402 B Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
  • Haier AB092ACBHA | User Manual - Page 2
    Contents Cautions 1-2 Main points of Operation 3-4 Name of Each part 5 Safety Cautions 6-7 Maintenance 8 Trouble shooting 9-11 When trouble happens 12 Customer Need-to-know 13 Installation Tools 14 Installation Procedures 15-22 Check and Test Run 23 Malfunction Judgement 24
  • Haier AB092ACBHA | User Manual - Page 3
    waste materials collecting centers and waste paper disposal services nearest to your house. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly
  • Haier AB092ACBHA | User Manual - Page 4
    or its service Inadequate repairs refrigerant spurts out 2.5m. and gets into eyes, it may result in 8.The appliance must be installation that the serious eye injuries. plug should be easily accessible after installation. Do not obstruct or cover the ventilation grille of the air conditioner
  • Haier AB092ACBHA | User Manual - Page 5
    interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place. 3
  • Haier AB092ACBHA | User Manual - Page 6
    Failure Compensation(to be applied for a necessary situation): After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again. Setting Method: When the remote controller is
  • Haier AB092ACBHA | User Manual - Page 7
    Each Part Indoor unit Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Electrical Components Case outdoor unit Air inlet Air Inlet Grille Air Filter (Inside of the Inlet Grille) Connecting piping and electrical wiring Air outlet Drain hose 5
  • Haier AB092ACBHA | User Manual - Page 8
    damages or endanger the userípersonal safety. INSTRUCTION: This information can ensure the correct time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred even in case of refrigerant leakage When air conditioner is removed and reinstalled
  • Haier AB092ACBHA | User Manual - Page 9
    to be placed on or stand on outdoor unit. The falling of goods and people may cause accidents. Donít clean air conditioner with water. Otherwise may cause shock. Don't operate the air conditioner with damp hands. Otherwise will be shocked. Only use correct type fuse. May not use wire or any other
  • Haier AB092ACBHA | User Manual - Page 10
    blots are opened for inlet grille easily up and down as well cheaning the air filter.After open it,lower the inlet grille using remote controller, the maximum 1 rotated clamps 90 degree as shown in the figure, hold the air filter and nearly in the horizontal direction slightly pull it out. Fixing
  • Haier AB092ACBHA | User Manual - Page 11
    Trouble shooting Seasonal Reserve Post-season Care Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor
  • Haier AB092ACBHA | User Manual - Page 12
    conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard It smells. During operation, white fog comes out
  • Haier AB092ACBHA | User Manual - Page 13
    Trouble shooting Air does not blow or the fan speed cannot be changed during drying. running for a while after unit automatically stops. Please check the following things about your air conditioner before making a service call. Unit fails to start. Is the power supply switch on ? Is city supply
  • Haier AB092ACBHA | User Manual - Page 14
    trouble happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air is observed,stop the operation of the air conditioner and contact your sales dealer. The fuse
  • Haier AB092ACBHA | User Manual - Page 15
    air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual : after finishing installation,confirm no refrigerant leakage. 13
  • Haier AB092ACBHA | User Manual - Page 16
    expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil Standard accessories The following parts mentioned in this manual are the installation accessories we prepared. No. Accessory parts 1 Remote controller 2 Battery 3 Wire clamp Heat
  • Haier AB092ACBHA | User Manual - Page 17
    Unit Selection of installation place Place strong enough to support unit weight, and will not cause vibration and noise affected by rain or direct sunlight and sea breeze. Place with enough space for smooth air flow. The unit cannot be installed on an unspecified metal frame (e.g. theft guard net).
  • Haier AB092ACBHA | User Manual - Page 18
    pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) ) concentrates and retains. (6) Place strong enough to support the unit weight. (7) No expensive articles such as panel (2) Prepare all piping (refrigerant,water drainage )and wires (
  • Haier AB092ACBHA | User Manual - Page 19
    Installation Procedures (3) Install a suspending bolt To support the unit weight ,anchor bolt should be used against the direction of water drainage,problem may occur on floating water leakage.) Nut (Prepare in feild) In the case of ceiling already exists Washer (Prepared in feild) (1)Install
  • Haier AB092ACBHA | User Manual - Page 20
    than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts
  • Haier AB092ACBHA | User Manual - Page 21
    Installation Procedures 4. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the
  • Haier AB092ACBHA | User Manual - Page 22
    possible. Both gas pipe and liquid pipe shall be heat insulation. No leakage in the flare. Spanner Joint Nut (3) Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and
  • Haier AB092ACBHA | User Manual - Page 23
    . 2-way valve 3-way valve CAUTION: If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 7 Valve rod cap 7 Valve rod cap 7 Service port cap 21
  • Haier AB092ACBHA | User Manual - Page 24
    storm. Be sure to use rubber-damping cushion to reduce unit vibration. 2.Installation of drain elbow Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure. Do not use drain elbow in cold
  • Haier AB092ACBHA | User Manual - Page 25
    Check and Test Run Other Instructions 1.Configuration of power supply Air conditioner must use special power supply system ( Over outward Installation check and test run Require customers to use air conditioner according to the operation manual. The items checked during test run,please mark in No
  • Haier AB092ACBHA | User Manual - Page 26
    Malfunction Judgement Malfunction judgement No. Malfunction code Malfunction cause Indoor unit LED1 Indoor unit LED2 ìPOWERî ìRUNî state time state time Remark 1 Power supply led Malfunction of the flash 1 time room temp.sensor flash 2 Power supply led Malfunction of the flash 2
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

No.0010572402
B
Operation & Installation
Manual
AB092ACBHA
AU092AABHA
(HBU-09HA03/R1(B))
AB122ACBHA
AU122AABHA
(HBU-12HA03/R1(B))
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
CASSETTE AIR CONDITIONER