Main points of Operation Wait a Prevent Cool Air Blowing Off minute In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off. Defrosting Function In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air conditioner will automatically back to running. Defrosting Running Hints The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects. Power Failure Compensation(to be applied for a necessary situation): After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again. Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the ìsleepingî button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times,the air conditioner will enter the state of power failure compenstation. Cancel Method:Press the ìsleepingî button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 timer,the power failure compensation mode will be cancelled. Note: When a power failure suddenly occurs during the air conditioner si working after the power after the power failure compensationis set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the ì Switch On/Off î button after the power comes again. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

4
Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run
immediately after the unit starts to prevent
the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat
exchanger, the air conditioner will automatically defrost a
few minutes. During defrosting, both indoor and outdoor
fan will stop running. When defrosting finished, air condi-
tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and
releases inside when in heating mode, therefore the
outside environmental temperature will affect heating
effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air
conditioner is working,it will resume the previous working state when the power is supplied
again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press
the ìsleepingî button on the remote controller 10 times within 5 seconds,and
after the buzzer rings 4 times,the air conditioner will enter the state of power
failure compenstation.
Cancel Method:Press the ìsleepingî button on the remote controller 10 times within 5 seconds,
and after the buzzer rings 2 timer,the power failure compensation mode will be
cancelled.
Note: When a power failure suddenly occurs during the air conditioner si working after the
power after the power failure compensationis set,if the air conditioner will not be used
for a long time, please cut off the power supply to prevent its operation from being res-
umed after the power is supplied again, or press the ì Switch On/Off î button after the
power comes again.
Wait a
minute
Defrosting Running