Installation Procedures 4. Installation of water drainage pipe (1) Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts, to make water hose straight. 1-1.5m slope over 1/100 Use the drainage hose and clip provided with unit. Insert water pipe into water plug until it reaches the white tape. Tighten the clip until head of the screw is less than 4mm from hose. Wind the ddrainage hose to the clip using seal pad for heat insulation. Insulate drainage hose in the room. Large size seal pad Clip (accessory) Clip Tape(white) Draingage hose 4mm below 5. Cautions for the water drainage lifting pipe Installation height of water drainage lifting pipe shall be less than 280mm There should be a right angle with unit ,300mm from unit. 75mm below 500mm below 220 500mm below 300mm below 1-1.5m Suspending bracket 280mm unter Drainage hose Water drainage lifting pipe Drainage hose Clip 220mm < Note > The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force. If several water hoses join together, of as per following procedures. Slope below 1/100 Connection drainage hose with a T-joint 100mm ¸ over Specifications of the selected drainage hoses shall meet the requirements for the unit running 14 Safety Cautions No goods or nobody is permitted to be placed on or stand on outdoor unit. The falling of goods and people may cause accidents. WARNING Donít clean air conditioner with water. Otherwise may cause shock. Don't operate the air conditioner with damp hands. Otherwise will be shocked. Only use correct type fuse. May not use wire or any other materials replacing fuse,otherwise may cause faults or fire accidents. Donít place any burning unit in the airflow of air conditioner,which may cause incomplete combustion No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident. Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt. Not permitted when running Connect earthing wire. Earthing wire should not be connected to the gas pipe, water pipe,lightning rod or phone line,incorrect earthing may cause shock. Use discharge pipe correctly to ensure efficient discharge. In correct pipe usage may cause water leaking. Air conditioner canít be be installed in the environment with inflammable gases. The inflammable gases near to air conditioner may cause fire hazard. Installed electrical-leaking circuit breaker. It easily causes electrical shock without circuit breaker. When use the fumigating insecticide donít operate air conditioner. Otherwise the poisonous chemicals may settle in air conditioner, which harm the health of chemical-allergic people. 7