Haier AB122ACBJA User Manual - Page 4
Specifications
View all Haier AB122ACBJA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Cautions Do not obstruct or cover the ventilation 5. The power cord should be self-provided and grille of the air conditioner. Do not put it should have got the Local authentication fingers or any other things into the certificate. inlet/outlet and swing louver. 6. The air breaker should be all-pole switch. Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit. Specifications and the distance between it's two connecters should no less than 3mm. 7. Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring The refrigerating circuit is leak-proof. regulations specified in national standard. The machine is adaptive in following 8. In socket, exactly distinguish earth wire with situation neutral wire and it is wrong to connect them 1. Applicable ambient temperature range: AB092/122ACBJA AB142/182ACBJA: together. 9. A leakage breaker must be installed. 10. Connection method is Y-connection .If the Rated Maximum Minimum power cord is damaged, it must be replaced DB C 27 32 Indoor Cooling WB C 19 23 outdoor DB C 35 43 WB C 24 26 Indoor DB C 20 27 Heating WB C 14.5 -- outdoor DB C 7 24 WB C 6 18 AB142/182ACBFA: 18 by professional people of manufacturer or its 14 -5 maintenance department or similar to avoid -- dangers. ***** 15 11. The air breaker and the power switch should -- installed the conveniently reachable place for -7 -- user. AB142ACBFA AB182ACBFA: Attention: Rated Maximum Minimum As a result of poor conditions of the electrical DB C 27 32 Indoor Cooling WB C 19 23 outdoor DB C 35 43 WB C 24 26 18 MAINS, shortly voltage drops can appear 14 10 when starting the EQUIPMENT. This can -- influence other equipment (et.Blinking of a Indoor DB C 20 27 Heating WB C 14.5 -- outdoor DB C 7 24 WB C 6 18 15 lamp). If the MAIN-IMPEDANCE Zmax< -- 0.3970617HM, such disturbance are not -7 -- expected. In case of need , you may contact 2. If the supply cord is damaged, it must be your local supply authority for further information. replaced by the manufacturer or its service agent or a similar qualified person. Other Instructions 3. If the fuse on PC board is broken, please 1. The waste battery should be disposed properly. change it with the type of T3.15A /250VAC. When throw away the waste batteries, please 4. Use copper wire only. The connecting cable perform in accordance with the local regulation. should be H05RN-F 3G(2.5mm2+H05RN-F 2. The indoor unit installation height is at least 1x 0.75mm2. The power cable should be 2.5m.certificate. H05RN-F 3G 2.5mm2.All the cables shall 051220********* have got the European authentication certificate. 2