Haier AB122XCERA User Manual

Haier AB122XCERA Manual

Haier AB122XCERA manual content summary:

  • Haier AB122XCERA | User Manual - Page 1
    R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER CASSETTE TYPE INDOOR UNITS OPERATION & INSTALLATION MANUAL AB092XCERA AB122XCERA AB142XCERA AB182XCERA No.0010577258 A Please read this manual carefully before usingthis air conditioner. Please keep this manual safely for future use.
  • Haier AB122XCERA | User Manual - Page 2
    Contents Cautions 1-2 Main Points of Operation 3-4 Parts and Functions 5 Safety Cautions 6-7 Maintenance 8-9 When Trouble Happens 10 Customer Need-to-know 11 Installation Procedures 12-17 Instructions to installation 18-19 Trouble Shooting 20-22
  • Haier AB122XCERA | User Manual - Page 3
    waste materials collecting centers and waste paper disposal services nearest to your house. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly
  • Haier AB122XCERA | User Manual - Page 4
    air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner air conditioner. In no case should children be allowed to sit on the outdoor unit. 2. If the supply cord is damaged, it must be replaced by the service AB092XCERA
  • Haier AB122XCERA | User Manual - Page 5
    interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place. 3
  • Haier AB122XCERA | User Manual - Page 6
    Failure Compensation(to be applied for a necessary situation): After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again. Setting Method: When the remote controller is
  • Haier AB122XCERA | User Manual - Page 7
    Parts and Functions Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Operating Control Panel Air Inlet Grille Air Filter (Inside of the Inlet Grille) 5
  • Haier AB122XCERA | User Manual - Page 8
    damages or endanger the userípersonal safety. INSTRUCTION: This information can ensure the correct time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred even in case of refrigerant leakage When air conditioner is removed and reinstalled
  • Haier AB122XCERA | User Manual - Page 9
    ,which may cause incomplete combustion No inflammable spray fluid should be permitted to be placed or used near to air conditioner,otherwise may cause fire accident. Air conditioner should be cleaned only after power supply is cut off to keep from shock or hurt. Not permitted when running
  • Haier AB122XCERA | User Manual - Page 10
    filter with water or vacuum cleaner. Use the detergent or neutral soapy water if the air filter is too dirty. Then rinse the air filter with water,and reinstall after drying. Caution: Do not clean the air filter with hot water over 40 C, otherwise may damage the filter. Sweep the filter carefully
  • Haier AB122XCERA | User Manual - Page 11
    to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat. Pre-season Care See that there is no obstacle blocking
  • Haier AB122XCERA | User Manual - Page 12
    Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEAT mode) Any obstacle exists at the air is observed,stop the operation of the air conditioner and contact your sales dealer. The fuse
  • Haier AB122XCERA | User Manual - Page 13
    air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual finishing installation, please confirm no refrigerant leakage. 11
  • Haier AB122XCERA | User Manual - Page 14
    pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) ) concentrates and retains. (6) Place strong enough to support the unit weight. (7) No expensive articles such as panel (2) Prepare all piping (refrigerant,water drainage )and wires (
  • Haier AB122XCERA | User Manual - Page 15
    Installation Procedures (3) Install a suspending bolt To support the unit weight ,anchor bolt should be against the direction of water drainage,problem may occur on floating water leakage.) Nut (Prepare in feild) In the case of ceiling already exists Washer (Prepared in feild) (1)Install unit
  • Haier AB122XCERA | User Manual - Page 16
    than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts
  • Haier AB122XCERA | User Manual - Page 17
    Installation Procedures 6. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the
  • Haier AB122XCERA | User Manual - Page 18
    To gas pipe To outdoor unit (1) Dimension of connecting pipe AB092XCERA AB122XCERA AB142XCERA AB182XCERA Gas pipe Liquid pipe Gas pipe Liquid pipe . No leakage in the flare. (3) Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare. The bending radius shall
  • Haier AB122XCERA | User Manual - Page 19
    Installation Procedures 8.Electrical Wiring Wiring methods: 1 Wiring method of ring terminal For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and
  • Haier AB122XCERA | User Manual - Page 20
    Instructions to installation 9. Indoor unit communication addresses setting CAUTION! FAIL when using the remote controller. A. Set the addresses only after the successful installation of the refrigerant pipes and connecting cables, and open all the stop valves; B. Please confirm that the indoor
  • Haier AB122XCERA | User Manual - Page 21
    Instructions to installation SW01 1 2 3 4 5 6 7 8 ON OFF SW03 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF INDOOR UNIT ADDRESS 1 2 3 1 2 3 4 5 6 7 8 ON 4 OFF 4. How to check the addresses? When finish all
  • Haier AB122XCERA | User Manual - Page 22
    conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it sometimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking sound is heard It smells. During operation, white fog comes out
  • Haier AB122XCERA | User Manual - Page 23
    Trouble Shooting Air does not blow or the fan speed cannot be changed during drying. running for a while after unit automatically stops. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Unit fails to start. Is city supply
  • Haier AB122XCERA | User Manual - Page 24
    indoor unit PCB Malfunction on outdoor unit 20 TIMES Check the outdoor unit failure code Note: 1. Please contact the installers or distributors when trouble happens to repair it. 2. Turn the power off and power on again, if the failure code recurs, please inform the franchiser. 3. Failrue codes
  • Haier AB122XCERA | User Manual - Page 25
    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266555, P.R.China Web Site: http://www.haier.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

No.0010577258
A
R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER
OPERATION & INSTALLATION MANUAL
AB092XCERA
AB122XCERA
AB142XCERA
AB182XCERA
Please read this manual carefully before usingthis air conditioner.
Please keep this manual safely for future use.
CASSETTE TYPE INDOOR UNITS