Haier AB122XCERA User Manual - Page 21
Setting method of temperature compensation For heating function only
View all Haier AB122XCERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Instructions to installation SW01 1 2 3 4 5 6 7 8 ON OFF SW03 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF 1 2 3 4 5 6 7 8 ON OFF INDOOR UNIT ADDRESS 1 2 3 1 2 3 4 5 6 7 8 ON 4 OFF 4. How to check the addresses? When finish all the above works, please power off and power on again to the whole system but set all the indoor units in STANDBY. Then continously press the emergency switch until you hear the buzzer sound 5 times(Pi Pi Pi Pi Pi), and then the TIMER LED board will show the address of this indoor unit. Press any key on the remote controller, it will exit the address checking precedure. 10.Setting method of temperature compensation (For heating function only) Set method of temperature compensation(-8 C~6 C) in heating mode with the remote controller. In 24 C heating mode,press sleep 7 times continuously.Indoor buzzer sounds 2 times,that show temp.compensatoin works.Swith on the unit in heating mode by the remote controller,press the time button to set the set temp. compensatoin. so the set temp. compensation=the current set temp.-24 C.For example,if the set temp. is 24 C,the temp.compensation is 0 C;if the set temp.is 25 C,the temp. compensation is 1 C;if the set temp.is 30 C,the temp. compensation is 6 C;if the set temp.is 23 C,the temp. compensation is -1 C;if the set temp.is 16 C,the temp. compensation is -8 C;If setting is finished, press ON/OFF button, then the unit quits the temp. compensation. 19