Haier AV08NMVERA Design Manual - Page 19
ÚÔàåÚÔàåÊÚà
View all Haier AV08NMVERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Indoor units 4-way cassette type Model Nominal cooling capacity(KW) Nominal heating capacity(KW) Electrical heating power(KW) /Current(A) Heating capacity at low temp.(KW) Electri- Power source(PH,V,Hz) cal chara- Operating current(A) cteristics Power consumption(KW) Fan type and Qty Fan Fan motor output(KW) characteris- Standard airflow(m3/h) tics Standard static pressure(Pa) Max. static pressure(Pa) Exterior dimensions(mm) Panel exterior dimensions(mm) Weight(unit,net/gross, Kg) Weight(panel, net/gross, Kg) Expansion mode Controller Gas piping(mm) Piping dimension Liquid piping(mm) Drain hose(mm) Noise level(dB(A)) H/M/L AB382MCERA AB482MCERA 11.2 14 12.5 16 / / 10 12.5 1,220~230,50 1,220~230,50 0.76 0.76 0.15 0.15 centrifugal*1 centrifugal*1 0.09 0.09 1800 1800 0 0 ---- ---- 840*840*280 840*840*280 950*950*80 950*950*80 38/40 38/40 6/9 6/9 Electronic expansion valve Wired controller/ wireless controller (optional) 15.88 15.88 9.52 9.52 32 32 37/35/31 44/40/36 Norminal condition: indoor temperature (cooling): 270CDB/190CWB, indoor temperature (heating): 200CDB/14.50CWB Outdoor temperature(cooling): 350CDB/240CWB, outdoor temperature(heating): 70CDB/60CWB The noise level will be measured in the third octave band limited values in the semi-anechoic chamber, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. G R U P A d.o.o. 19