Haier ES60H-T1 User Manual - Page 2
Cleaning and Maintenance, Q & A, Specifications, Packing List, Operating Instructions - service
View all Haier ES60H-T1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Operating Instructions Cleaning and Maintenance Q & A After finishing the installation of a new water heater, there is no water in its water tank, please open the tap water inlet valve and mixing valve, adjust the mixing valve to provide the most hot water, close the water outlet valve after water flows from the shower head or water outlet continuously (it means that the water tank is full of water) and turn on the water heater after confirming no water leakage at each joint. 3D heating mode After the water heater starts, it can automatically select the activation of 3D heating mode by detecting water temperature in the water tank and hot water flow. In the 3D heating mode, the water heater heats water at high power to provide more hot water. Water temperature in the water tank ≤69°C: If water flow is less than 2.5L/min, the 3D heating mode will not activate; if water flow is more than or equal to 2.5L/min, the 3D heating mode will activate. Water temperature in the water tank ≥70°C: If water flow is less than 3L/min, the 3D heating mode will not activate; if water flow is more than or equal to 3L/min, the 3D heating mode will activate. Description of operating modes The water heater allows you to choose the desired mode from the following operating modes according to your actual need: the "shower for a given number of persons" mode, the "delay shower" mode, the "warm-keeping at medium temperature" mode and "low electricity price at night" mode. Turn-on Plug in the water heater, the display screen will light up for 2s. Press the " (ON/OFF)" key (the water heater will enter the standby mode or the operating mode before power failure). The "shower for a given number of persons" mode: Press the " " key to set the number of persons to take a shower.* Shower for one person " Press the " key Shower for two persons Press the " " key Shower for three persons Press the " " key Clock calibration Clock calibration is done when the water heater is in power-on state. Press the " (hour)" key or the " (minute)" key, the clock will flash. Press the " (hour)" key continuously to set the hour. Press the " (minute)" key to set the minute. Press the " ", " ", " Night-elec technology " or " " to Preheat Heat preservation confirm the time setting (if no operation is made in 6s, the time setting will also be confirmed automatically). Note: The time setting of water heater adopts the 24-hour system. Please ensure correct clock setting, otherwise the "low electricity price at night" and "delay shower" modes will not function normally. The water heater will automatically heat water for the selected number of persons to take a shower. * Note: The water heaters with volume of 40L, 50L and 60L can be set as "shower for one person" or "shower for two persons", while those with volume of 80L can be set as "shower for one person", "shower for two persons" or "shower for three persons". The "warm-keeping at medium temperature" mode: Press the " Heat preservation " key, the water heater will enter the "warm-keeping at medium temperature" mode. In this mode, maximum heating temperature is 40°C and not adjustable. The "low electricity price at night" mode: Night-elec Press the " technology " key, the water heater will enter the "low electricity price at night" mode. In this mode, the water heater activates the heating or warm-keeping function during 00:00~06:00 according to the water temperature setting. ● According to the electricity price system in some regions, the electricity price during 00:00~06:00 is lower than that during other hours, so it is easy to achieve cost saving by selecting the "low electricity price at night". ● In this mode, the water heater does not heat or keep warm during those hours other than 00:00~06:00. The "delay shower" mode: Press the " Preheat " key, the water heater will enter the "delay shower" mode. In this mode, the water heater finishes heating water and keeps water warm before the delay time you set according to the water temperature setting. ● In this mode, you may switch to "delay ", "delay " or "delay " by pressing the " Preheat " key. ● You may set the time respectively for "delay " and "delay " by following the instructions in the section of "setting of the delay time". Power-down memory The water heater can memorize the operating mode before power-down. Setting of the delay time Press the " Preheat " key, the icon of "delay " mode and the icon of clock display will flash simultaneously, at which time you may set the "delay ". Press the " (hour)" key continuously to set the hour. Press the " (minute)" key continuously to set the minute. The setting of "delay " is the same as that of "delay ". Note: ● Please use the "delay shower" mode after calibrating the clock. ● You may set and store time respectively for "delay " and "delay ". Automatic temperature control Being set with the function of automatic temperature control, when the water heater heats water to the temperature corresponding to the "shower for a given number of persons" mode, it will enter the warm-keeping mode and the "warmkeeping" icon will light up. In the warm-keeping mode, the water heater will keep such a cycle that it automatically reheats water to the set temperature and then keep water warm. Cleaning and maintenance Warning! The water heater must be repaired and maintained by a qualified technician only. Improper operation may cause serious injury or property loss. Cleaning Cleaning of the exterior ● Be sure to disconnect the water heater from power supply before cleaning. ● Gently wipe the exterior with a piece of wet cloth and a little neutral detergent. Do not use gasoline or other solutions. Finally, wipe the exterior with a piece of dry cloth and keep the water heater dry. Do not use any detergent containing abrasive (e.g. toothpaste), acid, chemical solvent (e.g. alcohol) or polishing agent. Cleaning of the interior To keep high-efficiency operation, please clean heating tubes and inner water tank once every three years. At the time of cleaning, be careful not to damage the protective coating on the exterior of heating tubes and on the surface of inner water tank. ● Be sure to disconnect the water heater from power supply before cleaning the inner water tank. ● Before cleaning, close the water inlet valve, open the water outlet valve, remove the "shockproof wall" shell and magnesium rod (at this time, you may also check the loss of magnesium rod for timely replacement. Note: magnesium rod must be purchased additionally.), drain the water tank, and then open the water inlet valve to wash the inner water tank again and again for several minutes until clean water flows out, and finally reinstall the magnesium rod and "shockproof wall" shell in place. Check ● When the water heater is in use, check the relief valve once a month as follows: pull the small handle of relief valve at the side of water inlet pipe (be careful not to hurt your hands), if water flows out, it means the relief valve is in normal operation; if no water flows out, please contact local Haier after-sales service center; if the relief valve is damaged, please replace it with a new relief valve of the same specification. ● Ask an after-sales service technician for safety inspection on a regular basis, remove the scale of heating tubes in a timely manner and check the loss of magnesium rod, and if necessary, replace the magnesium rod in time. Nonuse for a long time If the water heater will not be used for a long time, please do as follows: 1. Close the tap water pipe valve. 2. Connect one end of drain pipe to the pressure relief vent of relief valve and then open the handle of relief valve. 3. Open the hot water valve fully (in the meanwhile, remove the hose of shower head from the water outlet valve; at this time, be careful to avoid scald by hot water) to drain the inner water tank. To avoid personal injury, when you use the water heater again, it is recommended to open the hot water valve before turning on the power switch of water heater to discharge the air in the pipe; at this time, smoking or other open flame is prohibited near the open valve. In addition, thoroughly check whether each component of the water heater is in good condition and confirm whether inner water tank is full of water before using the water heater. Q & A Phenomenon No water outflow Cold water flows out Water temperature does not reach the required temperature or a small amount of water flows out Water flow and water temperature are unstable The water heater fails to turn on or the display screen does not light up E1 is displayed E2 is displayed E3 is displayed Items to be confirmed ① Whether the water supply system is cut off or whether water pressure is too low ② Whether the water outlet is clogged or whether the hot water valve is opened ① Whether the hot water outlet is opened ② Whether water temperature is set properly ③ Whether the heating time is too short to heat water to the set temperature ④ Whether any component is damaged ① Whether current function mode is set correctly ② Whether tap water pressure is too high Whether tap water pressure is stable ① Whether power supply is connected well ② Whether any component is damaged Circuit failure ① Whether inner water tank is full of water ② Whether any component is damaged ① Whether room temperature is below -20� ② Whether the sensor is damaged Check Solutions Check and clean Check and open Moderately raise the set temperature, wait until the water heater heats water to the newly set temperature and then control cold and hot water flow via the mixing valve Wait until the water heater heats water to the set temperature (at this time, the "heating" icon goes out) and then use water If not ①②③, please contact the repair center Refer to the description o operating modes in the section of "Operating Instructions", select the "shower for a given number of persons" and moderately increase the number of persons to take a shower Reduce water flow of the mixing valve Reduce water flow of the mixing valve or use after water pressure becomes stable Check the power socket If not ①, please contact the repair center Please contact the repair center Turn off the water heater, fill inner water tank with water and turn on the water heater again If not ①, please contact the repair center Turn off the water heater and turn on it again when ambient temperature is above -19� , the water heater will return to normal state If not ①, please contact the repair center Specifications Packing List Schematic circuit diagram L: live wire (brown) N: neutral wire (blue) PE: ground wire (yellow and green) MT1/MT2: manual reset thermostat EH: heating tube RT: sensor Electric leakage coil Relay Relay Relay Display panel Appearance and components Front view Sectional view Side view A. Hot water outlet B. Cold water inlet C. Heating tube D. Enamel inner water tank E. Magnesium rod Technical data Model Volume Specified power supply Rated power Rated pressure Rated Grade tem- of pera- waterture proof Tap water pressure Net weight (storage) 0.8 Note: For the above parameters (dimensions and weight), permissible error is ±10%. Packing list Qty. Model Component Electric water heater (set) Relief valve and drain pipe (set) Expansion bolt (pc Expan- Operatsion ing hook Instruc(pc) tions (pc) Remote controller (pc) Water flow sensor (pc) Elbow (pc) Washer (pc) Hidden cover (pc)