Haier HBU-24CL03 User Manual - Page 14

Fan speed selection, Unit stop, Air flow direction adjust

Page 14 highlights

GUIDE TO OPERATION (4) Fan speed selection Press FAN button. For each press, fan speed changes as follows: LO MID HI AUTO AUTO COOoLperatiosntartwshernoom Unit runs at the speed displayed on LCD. tehmipsg.htehtraenmspe.tting. Ultra-faliorw In HEAT mode, warm air will blow out after a short period of time due to cold-draft prevention function. Temp.setting+2C Tesmept. ing In DRY mode, when room temp. becomes 2 C higher than temp. setting, unit will run intermittently at LO speed regardless of FAN setting. Orneachintgemps.etting,unit willruninmildDRYmode. (5) Air flow direction adjust After operation mode is selected, vertical flap will open automatically according to the mode. (6) Unit stop Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closes automatically. Hints As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. differenceis above 7 C . Temp. difference of 3-5 C will remove your fatigue. More than this, unit's load can be reduced and power consumption cut down as well. So, you'd better set a temp. diff of 3-5 C between indoor and outdoor temp. in COOL mode. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

GUIDE TO OPERATION
12
Press FAN button. For each press, fan speed changes
as follows:
(4) Fan speed selection
Unit runs at the speed displayed on LCD.
In HEAT mode, warm air will blow out after a short period
of time due to cold-draft prevention function.
In DRY mode, when room temp. becomes 2 C higher than
temp. setting, unit will run intermittently at LO speed
regardless of FAN setting.
AUTO
LO
MID
HI
AUTO
Press ON/OFF button.
Only time remains on LCD.
All indicators on indoor unit go out.
Vertical flap closes automatically.
(6) Unit stop
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more
helpful for a better air circulation.
As warm air flows upward in HEAT mode, adjusting air flow downward will be much more
helpful for a better air circulation.
Be careful not to catch a cold when cold air blows downward.
It is harmful to your health in summer to go frequently in and out of places where temp.
differenceis above 7 C . Temp. difference of 3-5 C will remove your fatigue.
More than this, unit's load can be reduced and power consumption cut down as well. So,
you'd better set a temp. diff of 3-5 C between indoor and outdoor temp. in COOL mode.
Hints
COOL
operation
starts
when
room
temp.
is
higher
than
temp.
setting.
On
reaching
temp.
setting,unit
will
run
in
mild
DRY
mode.
Ultra-low
air
flow
Temp.
setting+2
C
Temp.
seting
(5) Air flow direction adjust
After operation mode is selected, vertical flap will open automatically according to the mode.