Haier HBU-42CM03 User Manual - Page 4
T. 3.15A /250VAC.
View all Haier HBU-42CM03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
CAUTIONS All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries. Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit. 4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self-provided. The requirement of the power cable: Model AB242ACNAC AU242AANAC (HBU-24CL03/R1) AB282ACBAC AU282AABAC (HBU-28HL03/R1) AB242ACBAC AU242AABAC (HBU-24HL03/R1) H07RN-F 3G 4.0mm2 AB28NACNAC AU28NAANAC (HBU-28CM03/R1) AB36NACNAC AU36NAANAC (HBU-36CM03/R1) AB42NACNAC AU42NAANAC (HBU-42CM03/R1) AB36NACBAC AU36NAABAC (HBU-36HM03/R1) AB42NACBAC AU42NAABAC (HBU-42HM03/R1) H07RN-F 5G 2.5mm2 Specifications The refrigerating circuit is leak-proof. The connecting cable should be H05RN-F 4G 0.75mm. All the cables shall have got the European The machine is adaptive in following authentication certificate. situation 6. The breaker of the air conditioner should 1. Applicable ambient temperature range: Indoor Maximum: D.B / W.B 32 C/ 23 C Cooling Minimum: D.B / W.B 18 C/ 14 C Outdoor Maximum: D.B 43 C/ 26 C Minimum: D.B 15 C Indoor Maximum: D.B 27 C Minimum: D.B 20 C Heating Maximum: D.B / W.B 24 C/ 18 C Outdoor Minimum: D.B / W.B -7 C/ -8 C 2. If the supply cord is damaged, it must be be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring. 7. The waste battery shall be disposed properly. 8. The indoor unit installation height is at least 2.5m. 9. The power supply connects from the outdoor unit replaced by the manufacturer or its service agentor a similar qualified person. 3. If the fuse on PC board is broken please change it with the type of T. 3.15A /250VAC. 2