ALIGNMENTS AND ADJUSTMENTS Installation It is the responsibility of the installer to make certain that the range is properly adjusted at the time of installation. Situations caused by improper adjustments or improper installation are not covered under the warranty. Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance. Gas Range Conversion and Adjustment Guide The range will either be set for use with Liquefied Petroleum (LP) or Natural Gas. The factory setting is indicated on the serial plate. When set for Natural Gas operation, the pressure regulator will regulate the pressure to 4 inches water column. When set for LP Gas operation, the pressure regulator will regulate the gas to 10 inches water column pressure. On sealed burner models the main top must be removed to adjust regulator, burner orifices and thermostat from NAT to LP (propane) or vice versa. See illustration. Burner Cap (4) Attachment Screws (4) Pressure Regulator Burner Venturi Front (2) Main Top Partial View Backguard Push & Turn Valves Burner Venturi Rear (2) MAIN TOP /BURNER ASSEMBLY Main Top Ignitor Attachment Screw Attachment Screw Burner Bowl Burner Venturi BURNER HEAD ASSEMBLY Burner Head Paper Clip Ignitor Wire 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

13
ALIGNMENTS AND ADJUSTMENTS
Installation
It is the responsibility of the installer to make certain that the range is properly adjusted
at the time of installation. Situations caused by improper adjustments or improper
installation are not covered under the warranty. Any expenses incurred due to such
situations will not be paid by the manufacturer of the appliance.
Gas Range Conversion and Adjustment Guide
The range will either be set for use with Liquefied Petroleum (LP) or Natural Gas. The
factory setting is indicated on the serial plate. When set for Natural Gas operation, the
pressure regulator will regulate the pressure to 4 inches water column. When set for LP
Gas operation, the pressure regulator will regulate the gas to 10 inches water column
pressure.
On sealed burner models the main top must be removed to adjust regulator, burner
orifices and thermostat from NAT to LP (propane) or vice versa. See illustration.
Push & Turn Valves
Burner Venturi
Front (2)
Burner Venturi
Rear (2)
Burner Head
Paper Clip
Ignitor Wire
Burner Venturi
Burner Bowl
Attachment Screw
Ignitor Attachment
Screw
Main Top
Pressure Regulator
Attachment
Screws (4)
Burner Cap (4)
Main Top
Partial View
Backguard
MAIN T
OP
/BURNER
ASSEMBL
Y
BURNER HEAD
ASSEMBL
Y