Haier HSU-12HEK03 User Manual - Page 2

Necessary Tools for Installation

Page 2 highlights

Necessary Tools for Installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 10.Gas leakage detector or soap-and-water solution 11.Measuring tape 12.Reamer Drawing for the installation of indoor and outdoor units more than 5cm Accessory parts No. Accessory parts Number of articles 1 Remote controller 1 2 R-03 dry battery 2 more than 10cm 3 1 Mounting plate 4 1 Drain hose 5 4X50 Steel nail, cement 6 6 4X25 Screw Plastic cap 4 7 1 Drain-elbow 8 Guardring 1 9 Cushion 4 10 1 Pipe supporting plate Arrangement of piping directions Rear left Left Rear right Right Below Optional parts for piping Mark A Parts name Non-adhesive tape B Adhesive tape C Saddle(L.S) with screws D Connecting electric cable for indoor and outdoor E Drain hose F Heating insulating material G Piping hole cover more than 10cm A Attention must be paid to the rising up of drain hose more than 10cm more than 60cm more than 10cm D more than 15cm Note:Cooling only units don't have Drain-elbow The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper
12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from
to
in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
A
G
No.
Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Drain-elbow
Guardring
Cushion
1
1
2
3
4
5
6
7
8
9
10
2
1
1
6
4
1
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
Note:Cooling only units don't have Drain-elbow
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Attention must be paid to
the rising up of drain hose
A
D
more than 5cm
more than 10cm
more than 10cm
more than 10cm
more than 15cm
more than 60cm
more than 10cm
1