Indoor unit
View all Haier HSU-18HEK03 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Power cable: 3G1.0mm 1(N) 2(L) 34 Power cable: 3G1.0mm 3(C) Indoor unit Outdoor unit HSU-09LEK03/(DB) HSU-108CH09 HSU-12LEK03/(DB) HSU-138CH09 connecting wiring: 3G1.5mm +1X0.75mm Power cable: 3G1.0mm 3G1.0mm Indoor unit Outdoor unit HSU-12LEK13-M 34 Power cable: 3G1.5mm 3G2.0mm Indoor unit HSU-18LEK13 Outdoor unit 1 Indoor unit HSU-12HEK03 HSU-07HEK03 Outdoor unit HSU-09HEK03 HSU-18HEK03 34 5 Power cable: 3G2.5mm 4G0.75mm 2 Indoor unit HSU-24LEK13 Power cable: 3G1.5mm 4G0.75mm 2 2 34 5 Power cable: 3G2.5mm 6G0.75mm Outdoor unit 1(L) 2 (N) 1 Indoor unit { POWER HSU-18LEK03/(DB) Outdoor unit Indoor unit HSU-24HEK03 Outdoor unit LN BR BL POWER SUPPLY Y/G 3 Indoor unit Outdoor unit HSU-09LEK13 HSU-09LEK03 HSU-12LEK13 HSU-12LEK03 HSU-07LEK03 connecting wiring: -mod 07-12: 3G1.0mm Power cable: -mod 07-12: 3G1.0mm