Hayward 100K Btu Abg Or Spa H Propane Models: ABG1001 and H100ID1
Hayward 100K Btu Abg Or Spa H Propane Manual
View all Hayward 100K Btu Abg Or Spa H Propane manuals
Add to My Manuals
Save this manual to your list of manuals |
Hayward 100K Btu Abg Or Spa H Propane manual content summary:
- Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 1
Installation, Operation & Service Procedures Above Ground Pool Heater Models H100ID1 & ABG1001 Unit must be installed outdoors only and below an altitude of 2000 feet FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 2
Hayward pool heater pool heater pool heater and heat exchanger. 1. WATER FLOW THROUGH HEATER Water must be flowing through the heater to form on pool walls, in heater is restored before operating the heater. A bypass feature is also advantageous for service needs and for the ability to remove the heater - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 3
heater is located, the contractor must be properly licensed. WARNING: Failure to comply with the appliance installation instructions and service instructions in this manual Propane gas tanks must be located outdoors away from the pool and in accordance with the standard for storage and handling of - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 4
excess of 1⁄2 psig. The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure heater. Incorrect settings can cause improper operation. 1. Turn pump, main gas valve and heater power on. Start heater following lighting instructions - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 5
and follow instructions on the front cover of this manual. NOTE: Do not use the unit below 40°F temperature. Do not operate heater while an automatic pool cleaner is history of heart disease, circulatory problems, diabetes, or blood pressure problems should obtain their physician's advice before - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 6
Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Burner cleaning: If required, burners can be cleaned in the following manner: 1. Turn pump, main gas valve and heater power off. 2. Remove the gas manifold. 3. Remove the burners. 4. Brush burners with - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 7
Operating Instructions Figure 6 7 - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 8
Parts List & Illustration ITEM NO. DESCRIPTION 1. Jacket, Top 2. Combustion Blower 3. Blower Gasket (Jakel only) 4. High Limit Kit 5. Heat Exchanger Assembly 6. Water Pressure Switch 8. Control Module 9. Interlock Switch 10. Air Pressure Switch 11. Coupling 12. Grommet 1 1/2" - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 9
Hayward Pool Heater Certificate of Limited Warranty Limited heater warranty: TERMS AND COVERAGE: We warrant our pool heater to be free from defects in workmanship and materials under normal use and service. Pursuant to this warranty and subject to the Conditions and Exceptions indicated below: 1. - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 10
Notes: - Hayward 100K Btu Abg Or Spa H Propane | Models: ABG1001 and H100ID1 - Page 11
Installation, Operation & Service Procedures
Above Ground Pool Heater
Models H100ID1 & ABG1001
PATENT US6082993
1302507301
REV P 0811
FOR YOUR SAFETY
– Do not store or use gasoline or other flammable vapors or liq-
uids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance
•
Do not touch any electrical switch; do not
use any phone in your building
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
•
If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING: If the information in these instruc
-
tions is not followed exactly, a fire or explo
-
sion may result causing property damage,
personal injury, or death.
Unit must be installed outdoors only
and below an altitude of 2000 feet