Optional Remote Controls

Page 9 highlights

Lights Config. + to view/change Push to access Lights options Move to previous/next configuration menu Lights Name Pool Light Rotates between all available names Move to next menu item or previous/next configuration menu Lights Function Manual On/Off for manual on/off, countdown timer and timeclock functions Lights Relay Standard Rotates between Manual On/Off (default), Countdown Timer, Low Speed- Filter, Timeclock, Solar, and Super Chlorinate Move to next menu item Toggle between Standard (default), Dimmer and VSP Move to next menu item or previous/next configuration menu for all functions except solar, dimmer relay, super chlorinate and low speed Lights Interlock Toggle between Enabled and Disabled (default) Lights Interlock Disable Move to next menu item for all functions except solar, dimmer relay, super chlorinate pH dispense, low speed, and group Lights Ext Input Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu for all functions except dimmer relay, super chlorinate pH dispense, low speed, and group Lights Freeze Toggle between Enabled and Disabled (default) Lights Freeze Disable Move to previous/next configuration menu if filter pump is set to variable speed and the relay type is set to standard Lights Pump Spd Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest) Settings Menu Move to previous/next configuration menu Lights Function Although designated as the "Lights" output, the function of the lights relay is similar to the aux1 and aux2 relays. If pool lights are wired to the lights relay, some options including Solar function, Low Speed of a 2Speed Filter Pump, Lights Interlock and Lights Freeze Protection will not be necessary and should be disabled. If no pool lights are used, the lights relay can be used to control other pool devices that may require these options. The function of each option is shown below. Manual On/Off (default)-the lights relay will alternate between turning on and off when the LIGHTS button is pressed. There is no automatic control logic. Countdown Timer-the lights relay will turn on when the LIGHTS button is pressed. The lights relay will turn off automatically after a programmed time (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output off. Low Speed of a 2-speed Filter Pump - the Aqua Plus will turn on the lights relay whenever the low speed operation of the filter pump is required. It is very important that the "2-speed" filter pump option be selected under the "Filter Config." Menu for proper operation. Timeclock - the lights relay will turn-on and turn-off at the times set for the lights timeclock in the Timers Menu (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output on and off. Solar - the lights relay can operate a solar booster pump which will turn on when the filter pump is running and solar heat is available and the water is less than the desired temperature setting. It is important to note that "Solar Control" must be enabled in the "Solar Config." menu for proper operation to occur. Super Chlorinate - if "Chlorinator" is enabled, this option allows the user to start a Super Chlorinate cycle when the Lights button is pressed, rather than using the Settings Menu. Note that only one button can be assigned to this function. Lights Relay This feature allows the user to select either "Standard" (default), "Dimmer" or "VSP" type relay for the Lights output. The optional AQL-DIM dimmer kit must be installed if "Dimmer" is desired. When "Dimmer" is selected, and the Lights output is manually turned on, the "+" and "-" buttons adjust the level from 20% to 100% (default). The level is saved for the next time the lights are turned on. 25 Optional Remote Controls Hayward offers a variety of wired and wireless remote control options for the Aqua Plus. Each model gives you the ability to control your pool's functions from a remote location, away from the Control Center. Wired Remote Controls Up to 3 wired remote controls can be installed. See page 17 for wiring information. AQL-WW-P-4 The AQL-WW-P-4 display/keypad must be mounted indoors or in a weather protected area (rain should never touch the unit). The display/keypad is designed to mount onto a standard electrical utility box (same box as a single light switch, ideal for new construction) or can be mounted directly onto any wall surface. When selecting a location, note that the wire to the Aqua Plus main unit must be less than 500' long. Refer to the remote's installation instructions as well as the steps below: 1. Remove display/keypad baseplate from the cover by lifting up on the cover at the lower end of the keypad. See diagram below. Remote Keypad push up here to remove cover 2. Screw the baseplate in the desired position (screws supplied by installer). 3. See "Electrical Wiring" (page 17) for instructions on running the cable from theAqua Plus main unit to the remote display/keypad. AQL-SS-6B-x (x=W or B for White or Black) The AQL-SS-6B is a double insulated, waterproof device which is intended for installation at the water's edge. The remote control comes with an attached 150' cable and is typically installed at the tile-line of the spa wall, or in the deck, within arm's reach of a pool/spa occupant. Refer to the AQL-SS-6B installation manual for specific mounting and wiring information. Wireless Remote Controls Note that the Aqua Plus is compatible with AQL2 wireless remote controls only. A single AQL2-BASE-RF Base Station must be installed on the Aqua Plus in order to use any of the Hayward wireless remote controls. With the Base Station installed, there is no limit on the number of wireless remotes that can used. The maximum distance between the wireless remotes and the base station on the Aqua Plus main control unit is 400 feet (120m) line of sight or 200 feet (60m) through walls, etc. If in doubt about the distance, test operation before installing the remote. All wireless models 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

Optional Remote Controls
Hayward offers a variety of wired and wireless remote control options for the Aqua Plus.
Each model gives you the
ability to control your pool’s functions from a remote location, away from the Control Center.
Wired Remote Controls
Up to 3 wired remote controls can be installed.
See page 17 for wiring information.
AQL-WW-P-4
The AQL-WW-P-4 display/keypad must be mounted indoors or in a weather protected area (rain should never touch
the unit).
The display/keypad is designed to mount onto a standard electrical utility box (same box as a single light
switch, ideal for new construction) or can be mounted directly onto any wall surface. When selecting a location, note
that the wire to the Aqua Plus main unit must be less than 500’ long. Refer to the remote’s installation instructions as well
as the steps below:
1.
Remove display/keypad baseplate from the cover by lifting up on the cover at the lower end of the keypad. See
diagram below.
2.
Screw the baseplate in the desired position (screws supplied by installer).
3.
See “Electrical Wiring”
(page 17) for instructions on running the cable from the Aqua Plus main unit to the
remote display/keypad.
AQL-SS-6B-x
(x=W or B for White or Black)
The AQL-SS-6B is a double insulated, waterproof device which is intended for installation at the water's edge.
The
remote control comes with an attached 150’ cable and is typically installed at the tile-line of the spa wall, or in the deck,
within arm's reach of a pool/spa occupant.
Refer to the AQL-SS-6B installation manual for specific mounting and
wiring information.
Wireless Remote Controls
Note that the Aqua Plus is compatible with AQL2 wireless remote controls only.
A single AQL2-BASE-RF Base
Station must be installed on the Aqua Plus in order to use any of the Hayward wireless remote controls.
With the Base
Station installed, there is no limit on the number of wireless remotes that can used. The maximum distance between the
wireless remotes and the base station on the Aqua Plus main control unit is 400 feet (120m) line of sight or 200 feet
(60m) through walls, etc.
If in doubt about the distance, test operation before installing the remote. All wireless models
6
Lights Config.
+ to view/change
Lights Function
Manual On/Off
Lights Name
Pool Light
Lights Relay
Standard
Push to access Lights options
Rotates between
Manual On/Off (default), Countdown Timer, Low Speed- Filter,
Timeclock, Solar, and Super Chlorinate
Rotates between all available names
Toggle between Standard (default), Dimmer and VSP
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item or previous/next configuration menu
Lights Interlock
Disable
Lights Freeze
Disable
Toggle between Enabled and Disabled (default) Lights Interlock
Toggle between Enabled and Disabled (default) Lights Freeze
Move to next menu item
Move to previous/next configuration menu
for all functions except solar, dimmer relay,
super chlorinate and low speed
for all functions except solar, dimmer relay, super chlorinate
pH dispense, low speed, and group
f
pH dispense, low speed, and group
or all functions except dimmer relay, super chlorinate
if filter pump is set to variable speed
and the relay type is set to standard
for manual on/off, countdown
timer and timeclock functions
Lights Ext Input
Disabled
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
Lights Pump Spd
Settings Menu
Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu
Lights Function
Although designated as the “Lights” output, the function of the lights relay is similar to the aux1 and aux2
relays.
If pool lights are wired to the lights relay, some options including Solar function, Low Speed of a 2-
Speed Filter Pump, Lights Interlock and Lights Freeze Protection will not be necessary and should be
disabled.
If no pool lights are used, the lights relay can be used to control other pool devices that may
require these options.
The function of each option is shown below.
Manual On/Off (default)
—the lights relay will alternate between turning on and off when the LIGHTS
button is pressed.
There is no automatic control logic.
Countdown Timer
—the lights relay will turn on when the LIGHTS button is pressed.
The lights relay will
turn off automatically after a programmed time (see Timers Menu in Operation Manual).
The LIGHTS
button can also be used to turn the output off.
Low Speed of a 2-speed Filter Pump
– the Aqua Plus will turn on the lights relay whenever the low speed
operation of the filter pump is required.
It is very important that the “2-speed” filter pump option be
selected under the “Filter Config.” Menu for proper operation.
Timeclock
– the lights relay will turn-on and turn-off at the times set for the lights timeclock in the Timers
Menu (see Timers Menu in Operation Manual).
The LIGHTS button can also be used to turn the output
on and off.
Solar
– the lights relay can operate a solar booster pump which will turn on when the filter pump is running
and solar heat is available
and the water is less than the desired temperature setting.
It is important to note
that “Solar Control” must be enabled in the “Solar Config.” menu for proper operation to occur.
Super Chlorinate
– if “Chlorinator” is enabled, this option allows the user to start a Super Chlorinate cycle
when the Lights button is pressed, rather than using the Settings Menu.
Note that only one button can be
assigned to this function.
Lights Relay
This feature allows the user to select either “Standard” (default), “Dimmer” or “VSP” type relay for the
Lights output.
The optional AQL-DIM dimmer kit must be installed if “Dimmer” is desired.
When “Dimmer” is selected, and the Lights output is manually turned on, the “+” and “-” buttons adjust
the level from 20% to 100% (default).
The level is saved for the next time the lights are turned on.
25
Remote Keypad
to remove cover
push up here