Hayward Aqua Rite AQ-RT-PRO prior to Oct 08

Hayward Aqua Rite Manual

Hayward Aqua Rite manual content summary:

  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 1
    Shown with optional AQL-CHEM Chemistry Kit Electronic Chlorine Generator Operation and Installation Manual AQ-RT-PRO G LDLINE CON TROLS www.goldlinecontrols.com
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 2
    . • All field installed metal components such as rails, ladders, drains, or other similar hardware within 3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • NOTICE TO USERS: This control product is to
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 3
    Table of Contents OPERATION General 1 Water Chemistry 1 Controls 6 Information Menu 7 Settings Menu 9 Operation 11 Maintenance 12 INSTALLATION Mounting 13 Plumbing 14 Wiring 15 TROUBLESHOOTING Troubleshooting 18 WARRANTY Warranty 20
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 4
    offer the user a complete auto- mated system controlling both sanitization and pH balance. NOTE: Goldline does not recommend using the Aqua Rite Pro to generate bromine. NOTE: Before installing this product as part of a saline water purification system in a pool or spa using natural stone for
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 5
    enjoyment of the pool. Test your water periodically. Your authorized Aqua Rite Pro dealer or most pool stores can provide you with the chemicals and procedures to adjust the water chemistry. Be sure to tell the pool store that you are using an Aqua Rite Pro chlorine generator. Saturation index The
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 6
    2700-3400 ppm (parts per million) with 3200 ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua Rite Pro and result in low chlorine production. A high salt level can
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 7
    3200 PPM Current salt Gallons and (Liters) of Pool/Spa water level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000 ppm (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (97,500) (105,000)(112,500
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 8
    FOR 80 PPM Gallons and (Liters) of Pool/Spa water Current Stabilizer Level (ppm) 8,000 (30000) 10,000 12,000 (37500) (45000) 14,000 (52500) 16,000 (60000) 18,000 (67500) 20,000 (75000) 22,000 (82500) 24,000 (90000) 26,000 (97500) 28,000 30,000 32,000 34,000 36,000 38,000 40,000 (105000
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 9
    and the filter pump is running. STOP: When in STOP mode, the Aqua Rite Pro is prevented from energizing the electrolytic cell. In this position there is no chlorine generation. NOTE: To service any of the pool equipment or the Aqua Rite Pro, the power must be turned off at the circuit breaker. SUPER
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 10
    the use of AQL-CHEM Sensing Kit). The Aqua Rite Pro will refer to these levels to determine how much chlorine to generate (ORP) and how mfour cspheCcOifi2coirnafocridmtaotidoinspaebnosuet (pH). these Refer to levels as the AQL-CHEM manual well as the recommended ranges. +S2e3t.4D5ay an
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 11
    menu item For optimum operation, you will need to inspect the Aqua Rite Pro chlorinator cell approximately every 3 months and clean the cell if necessary. The Aqua Rite Pro will automatically remind you and display "Inspect Cell, hold + to reset" as part of the rotating Information Menu. Clean the
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 12
    of water over 1000 gallons. The Aqua Rite Pro will adjust its operation according to this selection. Display Allows for the display of salt (default) or mineral values. Cell Type Selection Make the proper selection based on the electrolytic cell that is used in your system. For pools up to 20,000
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 13
    pool Move to previous/next menu item The desired output % is used to control the amount of chlorine the Aqua Rite Pro generates. Raise this setting to increase chlorine level and lower it to decrease chlorine level. If an AQL-CHEM is being used and ORP Auto Sensing is enabled (see AQL-CHEM manual
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 14
    there are three factors that you can control which directly contribute to the amount of chlorine the Aqua Rite Pro will generate: 1. filter run time each day (hours) 2. the desired output % setting or ORP setting (when using AQL-CHEM) 3. the amount of salt in the pool The filter pump timer should be
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 15
    message "Inspect/Clean Cell" after approximately 500 hours of operation. The Aqua Rite Pro electrolytic cell has a self cleaning feature incorporated into the electronic control's logic. In most cases this self cleaning action will keep the cell working at optimum efficiency. In areas where water is
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 16
    the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer to the Aqua Rite Pro system. Mounting the Aqua Rite Pro Control The Aqua Rite Pro is
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 17
    -CHEM's probe cell to the pool plumbing. Refer to the AQL-CHEM manual for specific mounting instructions. Plumbing Ensure that the Aqua Rite Pro installation does not constitute a cross connection with the local potable water supply. Consult local plumbing codes. The flow switch and cell should be
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 18
    to the bottom of the Aqua Rite Pro enclosure (two lugs are provided for Canadian models). The Aqua Rite Pro must be bonded with an 8 AWG copper wire (6 AWG Canada) to the pool bonding system. Refer to the diagram below. Cutout for cell cable Bottom of Aqua Rite Pro Enclosure Second bonding lug for
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 19
    these connections. Flow Switch Connector Cell Connector Optional AQL-CHEM Chemistry Kit Plug the connector from the AQL-CHEM into the designated connector on the Aqua Rite Pro PCB as shown below. For detailed installation and operation information, refer to the AQL-CHEM instructions. Connector for
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 20
    Goldline Aqua Rite Chlorinator The Aqua Rite Pro can control one or more Goldline Aqua Rite chlorinators when additional sanitizing capacity is required. A 4 wire connection is used to communicate to the Aqua Rite(s) and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used.
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 21
    + to reset" as part of the rotating Default Menu. Clean the cell (see instructions, page 12) and then press the "+" button during the "Inspect Cell" display to reset the timer. • Low Salt/Minerals or Very Low Salt/Minerals -- when the salt is too low the Aqua Rite Pro will generate less chlorine and
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 22
    Aqua Rite Pro will stop generating chlorine under certain high salt conditions in order to protect the internal electronics from damage. The only way to lower the salt level is to partially drain the pool and add fresh water. • Chlorinator Cell Sensor -- the cell "+" button to reset the alarm and
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 23
    with the Goldline installation instructions and specifications provided with the product. If written proof of the date of the initial system installation is not provided to Goldline, the manufacturing datecode on the Aqua Rite, Aqua Rite Pro, Aqua Trol, Aqua Logic and Pro Logic electronics unit will
  • Hayward Aqua Rite | AQ-RT-PRO prior to Oct 08 - Page 24
    ppm Add calcium to increase. Drain and add water to decrease. Electrolytic Cell inspect & clean Refer to section in manual. Questions? Refer to www.goldlinecontrols.com for latest manual revisions, additional information and helpful service. QUARTERLY G LDLINE CON TROLS N. Kingstown, RI 02852
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Electronic Chlorine Generator
www.goldlinecontrols.com
LD
C
G
LINE
ON TROLS
Shown with optional AQL-CHEM Chemistry Kit
Operation and Installation
Manual
AQ-RT-PRO