Hayward TCELL925-W TCELL925 and TCELL925-W Configuration Guide

Hayward TCELL925-W Manual

Hayward TCELL925-W manual content summary:

  • Hayward TCELL925-W | TCELL925 and TCELL925-W Configuration Guide - Page 1
    CELL-9, GLX-CELL-9, or TCELL925-CUL, no re-configuration is necessary. You must configure your controller for use with the TCELL925/TCELL925-W chlorinator cell manual Cell Type" is displayed. 5. Push "+" or "-" until "T-CELL-9" is displayed. 6. Exit Settings Menu by pushing the "Menu" button. Hayward
  • Hayward TCELL925-W | TCELL925 and TCELL925-W Configuration Guide - Page 2
    INFORMATION Regarding Extended Pool Filtration cell can be installed vertically or in an inverted manner (see illustration) to keep it flooded with water. Vertical Installation Inverted Installation Desired installation configurations when using 2 speed or variable speed pumps. USE ONLY HAYWARD
  • Hayward TCELL925-W | TCELL925 and TCELL925-W Configuration Guide - Page 3
    vous remplacez une cellule existante de type T-CELL-9, GLX-CELL-9 ou TCELL925-CUL, une reconfiguration n'est pas nécessaire. Vous Cell Type » s'affiche. 5. Appuyez sur « + » ou « - » jusqu'à ce que « T-CELL-9 » s'affiche. 6. Quittez le menu des réglages en appuyant sur la touche « Menu ». Hayward
  • Hayward TCELL925-W | TCELL925 and TCELL925-W Configuration Guide - Page 4
    inversée (consultez l'illustration ci-dessous) afin qu'elle soit toujours pleine d'eau. Configurations d'installation souhaitables lorsqu'une pompe à 2 vitesses ou une pompe à vitesse variable est utilisée. Hayward is a registered trademark and AquaRite, AquaRite Pro, and ProLogic are trademarks of
  • 1
  • 2
  • 3
  • 4

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
092631 RevC
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
TCELL925
TCELL925-W
MENU SETTING MAY BE REQUIRED!
The TCELL925 and TCELL925-W are cells designed for pools up to 25,000 gallons. When replacing an existing T-CELL-9, GLX-CELL-9, or
TCELL925-CUL, no re-configuration is necessary.
You must configure your controller for use with the TCELL925/TCELL925-W chlorinator cell before attempting to operate. Incorrect configu-
ration will cause inaccurate salt readings, improper operation, and possible system shutdown. The TCELL925/TCELL925-W is designed for
pools up to 25,000 gallons and is compatible with the following models only and will NOT work with earlier versions:
AQR (AquaRite - all 2009 or later) - firmware version 1.5 or later
AQR-PRO (AquaRite Pro) - operating with firmware 1.10 or later
PL-P-4 (ProLogic P4) - operating with firmware 4.10 or later
PL-PS-x (ProLogic PS) - operating with firmware 4.10 or later
OmniLogic & OmniPL - refer to owner’s manual for configuration
AQR900 series - all units
Connecting to an AQR or AQR900:
1.
Slide the Main Switch to the “Auto” position.
2.
Push the Diagnostic button repeatedly until “t-xx” appears on the display (“t-15” is the factory default).
3.
To change cell type, slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”.
Repeat this process until the “t-9” is
displayed.
4.
Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1.
Verify that the firmware version is 1.10 or greater by pushing the “Info” button, then”>” repeatedly until the firmware revision is shown.
If the firmware version is less that 1.10, the TCELL925/TCELL925-W cannot be used.
2.
Access the Settings Menu by pushing the “Settings” button.
3.
Push “>” until Chlor. Config is displayed, then push “+”.
4.
Push “>” repeatedly until “Cell Type” is displayed.
5.
Push “+” or “-” until “T-CELL-9” is displayed.
6.
Exit Settings Menu by pushing the “Info” button.
Connecting to a PL-P-4 or PL-PS-x:
1.
Verify that the firmware version is greater than 4.10 by entering the Diagnostic Menu and repeatedly pushing the “>” until the Main
Firmware revision is shown.
If the firmware version is less that 4.10, the TCELL925/TCELL925-W cannot be used.
2.
Enter the Configuration Menu.
3.
Push “>” until Chlor. Config is displayed, then push “+”.
4.
With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
5.
Push “+” or “-” until “T-CELL-9” is displayed.
6.
Exit Settings Menu by pushing the “Menu” button.