092631 RevC TCELL925 TCELL925-W MENU SETTING MAY BE REQUIRED! The TCELL925 and TCELL925-W are cells designed for pools up to 25,000 gallons. When replacing an existing T-CELL-9, GLX-CELL-9, or TCELL925-CUL, no re-configuration is necessary. You must configure your controller for use with the TCELL925/TCELL925-W chlorinator cell before attempting to operate. Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown. The TCELL925/TCELL925-W is designed for pools up to 25,000 gallons and is compatible with the following models only and will NOT work with earlier versions: • AQR (AquaRite - all 2009 or later) - firmware version 1.5 or later • AQR-PRO (AquaRite Pro) - operating with firmware 1.10 or later • PL-P-4 (ProLogic P4) - operating with firmware 4.10 or later • PL-PS-x (ProLogic PS) - operating with firmware 4.10 or later • OmniLogic & OmniPL - refer to owner's manual for configuration • AQR900 series - all units Connecting to an AQR or AQR900: 1. Slide the Main Switch to the "Auto" position. 2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory default). 3. To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto". Repeat this process until the "t-9" is displayed. 4. Push the Diagnostic button to exit. Connecting to an AQR-PRO: 1. Verify that the firmware version is 1.10 or greater by pushing the "Info" button, then">" repeatedly until the firmware revision is shown. If the firmware version is less that 1.10, the TCELL925/TCELL925-W cannot be used. 2. Access the Settings Menu by pushing the "Settings" button. 3. Push ">" until Chlor. Config is displayed, then push "+". 4. Push ">" repeatedly until "Cell Type" is displayed. 5. Push "+" or "-" until "T-CELL-9" is displayed. 6. Exit Settings Menu by pushing the "Info" button. Connecting to a PL-P-4 or PL-PS-x: 1. Verify that the firmware version is greater than 4.10 by entering the Diagnostic Menu and repeatedly pushing the ">" until the Main Firmware revision is shown. If the firmware version is less that 4.10, the TCELL925/TCELL925-W cannot be used. 2. Enter the Configuration Menu. 3. Push ">" until Chlor. Config is displayed, then push "+". 4. With the Chlorinator Enabled, push ">" repeatedly until "Cell Type" is displayed. 5. Push "+" or "-" until "T-CELL-9" is displayed. 6. Exit Settings Menu by pushing the "Menu" button. Hayward Industries 400 Connell Drive, Suite 6100 Berkeley Heights, NJ 07922 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
092631 RevC
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
TCELL925
TCELL925-W
MENU SETTING MAY BE REQUIRED!
The TCELL925 and TCELL925-W are cells designed for pools up to 25,000 gallons. When replacing an existing T-CELL-9, GLX-CELL-9, or
TCELL925-CUL, no re-configuration is necessary.
You must configure your controller for use with the TCELL925/TCELL925-W chlorinator cell before attempting to operate. Incorrect configu-
ration will cause inaccurate salt readings, improper operation, and possible system shutdown. The TCELL925/TCELL925-W is designed for
pools up to 25,000 gallons and is compatible with the following models only and will NOT work with earlier versions:
AQR (AquaRite - all 2009 or later) - firmware version 1.5 or later
AQR-PRO (AquaRite Pro) - operating with firmware 1.10 or later
PL-P-4 (ProLogic P4) - operating with firmware 4.10 or later
PL-PS-x (ProLogic PS) - operating with firmware 4.10 or later
OmniLogic & OmniPL - refer to owner’s manual for configuration
AQR900 series - all units
Connecting to an AQR or AQR900:
1.
Slide the Main Switch to the “Auto” position.
2.
Push the Diagnostic button repeatedly until “t-xx” appears on the display (“t-15” is the factory default).
3.
To change cell type, slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”.
Repeat this process until the “t-9” is
displayed.
4.
Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1.
Verify that the firmware version is 1.10 or greater by pushing the “Info” button, then”>” repeatedly until the firmware revision is shown.
If the firmware version is less that 1.10, the TCELL925/TCELL925-W cannot be used.
2.
Access the Settings Menu by pushing the “Settings” button.
3.
Push “>” until Chlor. Config is displayed, then push “+”.
4.
Push “>” repeatedly until “Cell Type” is displayed.
5.
Push “+” or “-” until “T-CELL-9” is displayed.
6.
Exit Settings Menu by pushing the “Info” button.
Connecting to a PL-P-4 or PL-PS-x:
1.
Verify that the firmware version is greater than 4.10 by entering the Diagnostic Menu and repeatedly pushing the “>” until the Main
Firmware revision is shown.
If the firmware version is less that 4.10, the TCELL925/TCELL925-W cannot be used.
2.
Enter the Configuration Menu.
3.
Push “>” until Chlor. Config is displayed, then push “+”.
4.
With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
5.
Push “+” or “-” until “T-CELL-9” is displayed.
6.
Exit Settings Menu by pushing the “Menu” button.