Hayward W3T-CELL-15 T-CELL-15 and GLX-CELL-15-W Manual

Hayward W3T-CELL-15 Manual

Hayward W3T-CELL-15 manual content summary:

  • Hayward W3T-CELL-15 | T-CELL-15 and GLX-CELL-15-W Manual - Page 1
    T-CELL-15 or GLX-CELL-15-W chlorinator cell. Refer to the information below. Incorrect configuration will cause inaccurate salt readings until "Cell Type" is displayed. 4. Push "+" or "-" until "T-CELL-15" is displayed. 5. Exit Settings Menu by pushing the "Menu" button. Hayward Industries 400
  • Hayward W3T-CELL-15 | T-CELL-15 and GLX-CELL-15-W Manual - Page 2
    conditions THE AMOUNT OF CHLORINE PRODUCED BY YOUR HAYWARD/GOLDLINE SALT CHLORINE GENERATING SYSTEM IS DEPENDENT ON THE LENGTH OF salt cell is receiving adequate flow. Low flow conditions can result in insufficient water in the cell causing inefficient chlorine production. As a precaution, the cell
  • 1
  • 2

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
T-CELL-15 & GLX-CELL-15-W
(New Menu Setting May Be Required)
The T-CELL-15 and GLX-CELL-15-W are designed for pools up to 40,000 gallons. When replacing an existing T-CELL-15 or
GLX-CELL-15, no re-configuration is necessary.
Configuration of your controller may be required before using the T-CELL-15 or GLX-CELL-15-W chlorinator cell.
Refer to the
information below. Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shut-
down.
CONFIGURATION is necessary with the following models:
AQR (Aqua Rite - all 2009 or later) - firmware version 1.5 or later
AQR-PRO (Aqua Rite Pro)
PL-P-4 (Pro Logic P4)
PL-PS-x (Pro Logic PS)
AQ-LOGIC-P-4 (Pro Logic P4)
AQ-LOGIC-PS-x (Pro Logic PS)
NO CONFIGURATION is neccessary with the following models:
AQ-RITE (Aqua Rite - 2008 and earlier) - firmware earlier than version 1.5
AQ-RITE-XL (Aqua Rite XL)
Connecting to an AQR:
1.
Slide the Main Switch to the “Auto” position.
2.
Push the Diagnostic button repeatedly until “t-xx” appears on the display (“t-15” is the factory default). If “t-15” is dis-
played, skip to step 4.
3.
To change cell type, slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”.
Repeat this process until
the “t-15” is displayed.
4.
Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1.
Access the Settings Menu by pushing the “Settings” button.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
Push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Info” button.
Connecting to an AQ-LOGIC-P-4, AQ-LOGIC-PS-x, PL-P-4 or PL-PS-x:
1.
Enter the Configuration Menu.
2.
Push “>” until Chlor. Config is displayed, then push “+”.
3.
With the Chlorinator Enabled, push “>” repeatedly until “Cell Type” is displayed.
4.
Push “+” or “-” until “T-CELL-15” is displayed.
5.
Exit Settings Menu by pushing the “Menu” button.
092409A RevD