HP 1032 HP High Performance Clusters LC 1000 Series Cabling Guide - Page 54

Table 11-1, Cable Label Nomenclature

Page 54 highlights

64 Node Myrinet Expandable to 128 Nodes Point-to-Point Cabling Guide Table 11-1: Cable Label Nomenclature Symbol R S SW M P NIC SER PCI Description Rack number Control/Compute/Storage node number Out of Band (OOB) Management Switch/Cluster Interconnect Switch/In Band (IB) Management Switch number Module letter or Module number Port number NIC port number Serial port Myrinet Adapter (in PCI slot) Table 11-2: 64 Node Myrinet Cabling for DL140 LC Clusters Expandable to 128 Nodes OOB Switch Cabling Origin (server) Destination (switch) R1-S1-SER R1-SW2-P1 R1-S2-SER R1-SW2-P2 R1-S3-SER R1-SW2-P3 R1-S4-SER R1-SW2-P4 R1-S5-SER R1-SW2-P5 R1-S6-SER R1-SW2-P6 R1-S7-SER R1-SW2-P7 R1-S8-SER R1-SW2-P8 R1-S9-SER R1-SW2-P9 R1-S10-SER R1-SW2-P10 R1-S11-SER R1-SW2-P11 R1-S12-SER R1-SW2-P12 R1-S13-SER R1-SW2-P13 Cluster Interconnect Switch Cabling Origin (server) Destination (switch) R1-S1-PCI R2-SW1-M4-P12 R1-S2-PCI R2-SW1-M4-P13 R1-S3-PCI R2-SW1-M4-P14 R1-S4-PCI R2-SW1-M4-P15 R1-S5-PCI R2-SW1-M5-P8 R1-S6-PCI R2-SW1-M5-P9 R1-S7-PCI R2-SW1-M5-P10 R1-S8-PCI R2-SW1-M5-P11 R1-S9-PCI R2-SW1-M5-P12 R1-S10-PCI R2-SW1-M5-P13 R1-S11-PCI R2-SW1-M5-P14 R1-S12-PCI R2-SW1-M5-P15 R1-S13-PCI R2-SW1-M6-P8 IB Management Switch Cabling Origin (server) Destination (switch) R1-S1-NIC2 R1-SW1-P1 R1-S2-NIC2 R1-SW1-P2 R1-S3-NIC2 R1-SW1-P3 R1-S4-NIC2 R1-SW1-P4 R1-S5-NIC2 R1-SW1-P5 R1-S6-NIC2 R1-SW1-P6 R1-S7-NIC2 R1-SW1-P7 R1-S8-NIC2 R1-SW1-P8 R1-S9-NIC2 R1-SW1-P9 R1-S10-NIC2 R1-SW1-P10 R1-S11-NIC2 R1-SW1-P11 R1-S12-NIC2 R1-SW1-P12 R1-S13-NIC2 R1-SW1-P13 continued HP High Performance Clusters LC 1000 Series Cabling Guide 11-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

64 Node Myrinet Expandable to 128 Nodes
Point-to-Point Cabling Guide
Table 11-1:
Cable Label Nomenclature
Symbol
Description
R
Rack number
S
Control/Compute/Storage node number
SW
Out of Band (OOB) Management Switch/Cluster Interconnect Switch/In Band (IB)
Management Switch number
M
Module letter or Module number
P
Port number
NIC
NIC port number
SER
Serial port
PCI
Myrinet Adapter (in PCI slot)
Table 11-2:
64 Node Myrinet Cabling for DL140 LC Clusters Expandable to 128 Nodes
OOB Switch Cabling
Cluster Interconnect Switch Cabling
IB Management Switch Cabling
Origin (server)
Destination
(switch)
Origin (server)
Destination
(switch)
Origin (server)
Destination
(switch)
R1-S1-SER
R1-SW2-P1
R1-S1-PCI
R2-SW1-M4-P12
R1-S1-NIC2
R1-SW1-P1
R1-S2-SER
R1-SW2-P2
R1-S2-PCI
R2-SW1-M4-P13
R1-S2-NIC2
R1-SW1-P2
R1-S3-SER
R1-SW2-P3
R1-S3-PCI
R2-SW1-M4-P14
R1-S3-NIC2
R1-SW1-P3
R1-S4-SER
R1-SW2-P4
R1-S4-PCI
R2-SW1-M4-P15
R1-S4-NIC2
R1-SW1-P4
R1-S5-SER
R1-SW2-P5
R1-S5-PCI
R2-SW1-M5-P8
R1-S5-NIC2
R1-SW1-P5
R1-S6-SER
R1-SW2-P6
R1-S6-PCI
R2-SW1-M5-P9
R1-S6-NIC2
R1-SW1-P6
R1-S7-SER
R1-SW2-P7
R1-S7-PCI
R2-SW1-M5-P10
R1-S7-NIC2
R1-SW1-P7
R1-S8-SER
R1-SW2-P8
R1-S8-PCI
R2-SW1-M5-P11
R1-S8-NIC2
R1-SW1-P8
R1-S9-SER
R1-SW2-P9
R1-S9-PCI
R2-SW1-M5-P12
R1-S9-NIC2
R1-SW1-P9
R1-S10-SER
R1-SW2-P10
R1-S10-PCI
R2-SW1-M5-P13
R1-S10-NIC2
R1-SW1-P10
R1-S11-SER
R1-SW2-P11
R1-S11-PCI
R2-SW1-M5-P14
R1-S11-NIC2
R1-SW1-P11
R1-S12-SER
R1-SW2-P12
R1-S12-PCI
R2-SW1-M5-P15
R1-S12-NIC2
R1-SW1-P12
R1-S13-SER
R1-SW2-P13
R1-S13-PCI
R2-SW1-M6-P8
R1-S13-NIC2
R1-SW1-P13
continued
HP High Performance Clusters LC 1000 Series Cabling Guide
11-3